background image

  

4

  

5

  Assembly and installation 81389

  Assembly and installation 81552

The length of the overflow pipe can be adjusted by pulling apart or pushing together 
the inner and outer overflow pipes.
Should you need to reduce the length even more, pull the outer overflow out of the 
collet, cut both the outer overflow pipe and the inner overflow pipe to the required 
length, remove any burrs and reassembly.  
Ensure all calculations are correct before cutting pipes.  
Remove the blanking plug(s) from the overflow assembly. Using PTFE tape fit the inlet 
elbow(s).
Push the rubber seal onto the overflow/waste assembly, and from the outside push 
the shaft through the bath overflow hole and hold in place. 
Slide the overflow housing onto the waste assembly and push up until it meets the 
bath, make sure that the slots for filling and overflow are on the underside. Secure 
using the retaining nut and tighten (do not over tighten as this may damage the parts 
and/or the bath).
Push the handle onto the assembly, with the small lever at the 12 o’clock position, 
secure the handle using the grub screw in the underside and tighten with the 
supplied allen key, push on the screw cover.
Connect to the supply pipework.

Overflow/waste 

assembly

Retaining nut

Rubber seal

Overflow 

housing

Handle

Inlet elbow

Screw cover

Inlet elbow

Cable to pop 

up waste

Inner overflow pipe

Outer overflow pipe

Collet

Push the seal onto the waste assembly
From below push the assembly up under the hole in the bath, and hold in place.
From inside the bath screw the waste flange into the assembly and tighten by hand, 
(do not over tighten as this may damage the parts and/or the bath).
Slide the compression nut, washer and seal over the pipe, push the pipe fully into the 
waste assembly, slide along the seal and washer and finally screw on the nut, hand 
tight only.
Screw on the plug.

Decreasing the pipe length.

The pipe can be shortened by carefully cutting, removing any burrs. 
Ensure all calculations are correct before cutting the pipe. 
Finish by following the above procedure.

Operation

Plug

Seal

Seal

Compression 

nut

Washer

Seal

Overflow/waste 

assembly

Overflow pipe

Waste flange 

with seal

Push down again to close the plug.

Push down to open the plug. 

Summary of Contents for WG-81389-C

Page 1: ...ve received from you the completed Guarantee Registration Form Vado accepts no responsibility for any forms lost in the post and returns by registered means is therefore recommended Under this guarantee which is non transferable Vado will at its option repair or replace free of charge any product or replacement part found to be defective The guarantee does not extend to any consequential loss or d...

Page 2: ...g UK BS6700 Regulations We strongly recommend that you use a qualified and registered plumber Installer must comply with current regulations Please note if installing in an enclosed environment access should be left for servicing and maintenance No costs relating to inadequate access can be accepted Care of the waste Our products are finished to the highest standard and due care needs to be taken ...

Page 3: ...ting screw Locking nut Operation Turning the handle anti clockwise closes the plug Turning the handle clockwise opens the plug Assembly and installation 81389 The length of the overflow pipe can be adjusted by pulling apart or pushing together the inner and outer overflow pipes Should you need to reduce the length even more pull the outer overflow out of the collet cut both the outer overflow pipe...

Page 4: ...mall lever at the 12 o clock position secure the handle using the grub screw in the underside and tighten with the supplied allen key push on the screw cover Connect to the supply pipework Overflow waste assembly Retaining nut Rubber seal Overflow housing Handle Inlet elbow Screw cover Inlet elbow Cable to pop up waste Inner overflow pipe Outer overflow pipe Collet Push the seal onto the waste ass...

Reviews: