25
Before connecting the system piping to the pump, the unit is to be securely fastened to the
bulkhead. Long or heavy piping sections shall not be supported from the pump but by separate
supports.
ALIGNMENT: No inspection or corrections to pump/motor alignment are necessary.
Install the oil reservoir and top up the reservoir with the supplied oil.
WARNING:
THE OIL RESERVOIR SHALL ALWAYS BE SUFFICIENTLY FILLED WITH OIL, AS
THE PROPER FUNCTIONING OF THE GAS SEAL LOCATED IN THE CENTRE OF
THE PUMP MAIN PLATE RELIES ON THE PRESENCE OF OIL, FOR LUBRICATING,
SEALING AND COOLING PURPOSES.
6.3.3 Electrical
installation
pump
Verify the power supply. This is to match the data as shown on the electric motor nameplate.
Grounding is to be carried out utilizing the grounding bolt located inside the terminal box, before the
motor is connected to the mains.
6.3.4 First
start
CAUTION:
UNDER NO CIRCUMSTANCES SHOULD THE PUMP RUN WITHOUT LIQUID.
THE PUMP HOUSING MUST FIRST BE FILLED WITH LIQUID, OTHERWISE THE
PUMP WILL SEIZE AND DAMAGE WILL OCCUR.
6.3.4.1 Self
priming
The pump will not function or prime until the casing is filled with liquid. Make sure any discharge
valve is opened before starting, enabling air to be released. Running the pump with zero capacity
will cause excessive system pressure; heat generated in the pump and may overload the electric
motor. Make sure any system valve should be fully opened when the pump is being started or
stopped.
6.3.4.2 Direction
of
rotation
This can be seen or checked from the motor side only. Make sure that all piping is installed, and the
pump is filled with water. Switch-on the pump unit for a short moment only! Look at the motor fan
and notice the direction in which the fan spins. This must be clockwise, when looking from the back
cover of the motor. An arrow also indicates correct direction of rotation. If direction of rotation is
wrong, interchange any of two line wires of the power cable in the terminal box.
Reference drawings:
Dimensional drawing sample pump/motor Ballast Monitor Mark 6
0806-1076
Electrical connection diagram Ballast Monitor Mark 6M MEPC 108(49)
0806-2048
Schematic installation diagram Oilcon Monitor System with 1x dP/I
transmitter
Mark
6
0806-8035
Bulkhead penetration and piping diagram Mark 6M
0806-8038
Summary of Contents for OILCON MARK 6M
Page 112: ...111...
Page 113: ...112...
Page 114: ...113...
Page 115: ...114...
Page 116: ...115...
Page 117: ...116...
Page 118: ...117...
Page 119: ...118...
Page 120: ...119...
Page 121: ...120...
Page 122: ...121...
Page 123: ...122...
Page 124: ...123...
Page 125: ...124...
Page 128: ...127 Drawing 1 0806 0005 Sheet 1 2...
Page 129: ...128 Drawing 2 0806 0005 Sheet 2 2...
Page 130: ...129 Drawing 3 0806 1041...
Page 131: ...130 Drawing 4 0806 1075...
Page 132: ...131 Drawing 5 0806 1076...
Page 133: ...132 Drawing 6 0806 1077...
Page 134: ...133 Drawing 7 0806 1260 Sheet 1 2...
Page 135: ...134 Drawing 8 0806 1260 Sheet 2 2...
Page 136: ...135 Drawing 9 0806 1265...
Page 137: ...136 Drawing 10 0806 1267...
Page 138: ...137 Drawing 11 0806 1268...
Page 139: ...138 Drawing 12 0806 1279...
Page 140: ...139 Drawing 13 0806 1285...
Page 141: ...140 Drawing 14 0806 1286...
Page 142: ...141 Drawing 15 0806 1287...
Page 143: ...142 Drawing 16 0806 1288...
Page 144: ...143 Drawing 17 0806 1621...
Page 145: ...144 Drawing 18 0806 1622...
Page 146: ...145 Drawing 19 0806 2032...
Page 147: ...146 Drawing 20 0806 2048...
Page 148: ...147 Drawing 21 0806 2050...
Page 149: ...148 Drawing 22 0806 5019...
Page 150: ...149 Drawing 23 0806 5026...
Page 151: ...150 Drawing 24 0806 8016...
Page 152: ...151 Drawing 25 0806 8023...
Page 153: ...152 Drawing 26 0806 8035...
Page 154: ...153 Drawing 27 0806 8038 Sheet 1 4...
Page 155: ...154 Drawing 28 0806 8038 Sheet 2 4...
Page 156: ...155 Drawing 29 0806 8038 Sheet 3 4...
Page 157: ...156 Drawing 30 0806 8038 Sheet 4 4...
Page 158: ...157 Drawing 31 0806 8039...
Page 159: ...158 Drawing 32 0806 8040...
Page 160: ...159 Drawing 33 0806 8070...
Page 161: ...160 Drawing 34 0810 2010...
Page 162: ...161 Drawing 35 0871 1213...
Page 163: ...162 Drawing 36 0899 1092...
Page 164: ...163 Drawing 37 0899 1163...
Page 165: ...164 Drawing 38 0899 1249...
Page 166: ...165 Drawing 39 0899 1256...
Page 167: ...166 Drawing 40 0899 1258...
Page 168: ...167 Drawing 41 0899 1259...