3
Parameters of product range
Specification
Model
RH(C)25L
RH(C)35L
RH(C)50L
F
u
n
cti
on
Heating capacity Kw
(air 2
6℃
, water 26
℃
)
10
13.5
17.5
C.O.P. (air26
℃
,water26
℃
)
6.6
7
6.7
Heating capacity Kw
(air 15
℃
,water 26
℃
)
6.6
9.9
11.4
C.O.P. (air 15
℃
,water26
℃
)
4.64
4.78
4.68
Cooling capacity Kw
(air 35
℃
,water 28
℃
)
6
8
10
C.O.P. (air35
℃
,water28
℃
)
4
4
3.8
Power supply
230-240V/1Ph/50Hz
Rated Input power
Kw
1.4
2.1
2.4
Rated Input current A
6.5
9.5
11.4
Advised water flux m³/h
4-6
5-7
6.5-8.5
Water pipe in-out spec
mm
50
50
50
Net weight / Gross weight Kg
68/78
70/80
72/82
*C.O.P: Coefficient of performance
Note:
1.
Mode RH~ is heating only, RHC is heating and cooling optional. For heating only, please ignore the parameters of
cooling capacity and cooling C.O.P, other parameters are the same with the heating and cooling type
2.
This product can work well under air temp +0
℃
~43
℃
. Performance cannot be guaranteed outside the
operating ranges and must take account the exterior conditions of use identified to select suitable mode
(such as location, volume of swimming pool, and numbers of swimmer.)
3.
Above parameters are subjected to adjustment periodically for technical improvement with further notice.
Please refer to nameplate on each machine for accurate information.