LAYOUT AND FUNCTION
17
4.3
Assembly overview
4.3.1
Straight sections
The insulating housings can hold up to 10 conductor rail profiles and provide reliable insulation. Shorter
lengths can be supplied. The ground conductor is marked with a continuous yellow stripe. The asymmetrical
design reliably prevents phase reversal during installation.
Connecting material, see 4.3.3
For the following table the types must be added:
e.g. VKS10-6/63-2000HSA for 2 m ID no. 780 042. HS = with PE
The 4-digit number (in bold) in the type designation indicates the length of the straight section in mm.
The last digit of the ID no. • indicates the individual length in meters. Please add 1, 2, 3, 4, 5 or 6 to the ID no.
VKS10
Standard lengths [m] 6
Deep-freeze ware-
house [m] 4
Weight [kg] max. 24
Permissible start/end
protrusion at the hang-
er [mm] max. 300
Material
Plastic
Conductor rail profile
E-Cu
Conductor rail protrusion 34 mm at 20° C UT
Type
Weight
[kg/m]
Nominal
cur-
rent
(5)
[A]
Nominal
current
(4)
[V]
Conductor cross section
L1-L3 PE 5-10
(3)
Num-
ber of
poles
ID no.
VKS10-4/63-....HSA
2.020
63
690
3x16
1x16
-
4
780 99•
VKS10-4/100-....HSA
2.250
100
690
3x25
1x16
-
4
780 71•
VKS10-4/120-....HSA
2.359
120
690
3x30
1x16
-
4
780 90•
VKS10-4/140-....HSA
2.520
140
(1)
690
3x35
1x16
-
4
780 68•
VKS10-5/63-....HSA
2.156
63
690
3x16
1x16
1x16
5
780 61•
VKS10-5/100-....HSA
2.384
100
690
3x25
1x16
1x16
5
780 70•
VKS10-5/120-....HSA
2.729
120
690
3x30
1x16
1x16
5
780 62•
VKS10-5/140-....HSA
2.864
140
(1)
690
3x35
1x16
1x16
5
781 28•
VKS10-6/63-....HSA
2.300
63
690
3x16
1x16
2x16
6
780 04•
VKS10-6/100-....HSA
2.540
100
690
3x25
1x16
2x16
6
780 05•
VKS10-6/120-....HSA
2.640
120
690
3x30
1x16
2x16
6
780 06•
VKS10-6/140-....HSA
2.810
140
(1)
690
3x35
1x16
2x16
6
780 07•
VKS10-7/63-....HSA
2.450
63
690
3x16
1x16
3x16
7
780 03•
VKS10-7/100-....HSA
2.680
100
690
3x25
1x16
3x16
7
780 08•
VKS10-7/120-....HSA
2.810
120
690
3x30
1x16
3x16
7
780 09•
VKS10-7/140-....HSA
2.950
140
(1)
690
3x35
1x16
3x16
7
780 01•
Summary of Contents for VKS10
Page 89: ...MAINTENANCE 87 Connecting caps mast assembly before Connecting caps mast assembly after ...
Page 96: ...PROTECTIVE MEASURES 94 10 PROTECTIVE MEASURES 10 1 EU conformity declaration ...
Page 99: ...CE Technical Documentation DQS certified in accordance DIN EN ISO 9001 2015 OHSAS 18001 2007 ...