LAYOUT AND FUNCTION
20
4.3.2
Curved section
Curved sections are supplied with straight connec-
tion ends of 250 mm length on both sides. Small radii
on request.
4.3.3
Connecting material
The connecting material is used for electrical and me-
chanical connection. The insulating housings are
connected with one-piece connector cover caps, the
conductor rail profiles are connected with spring-
loaded copper plug connectors.
Where hall expansion joints are present, use expan-
sion joint sections (on request).
Curved section
Min. Cu cross section
[mm
2
] 25
Curve length, max. [m] 5.3
Hanger spacing [m]
≈
0.6
Angle, max.
180°
Inner curve
Inner conductor
Outer curve
Outer conductor
(not pictured)
Type
R [mm]
ID no.
Inner curve, lateral (R > 1000)
≥
1000
780 344
Outer curve, lateral (R > 1500)
≥
1500
780 345
Connecting material
1
Plug connector for 63-
100 A / 120-140 A.
Differentiation by marking
on connector.
2
Connecting cap (plastic)
Plug connector
E-Cu
Type
Weight [kg]
Number of poles
ID no.
VM-SV10-4/63-100
0.385
4
781 321
VM-SV10-4/120-140
0.385
4
781 323
VM-SV10-5/63-100
0.400
5
781 315
VM-SV10-5/120-140
0.400
5
781 277
VM-SV10-6/63-100
0.415
6
781 150
VM-SV10-6/120-140
0.415
6
781 152
VM-SV10-7/63-100
0.430
7
781 153
VM-SV10-7/120-140
0.430
7
781 155