COMMISSIONING
68
Tolerances
NOTICE!
►
The permissible operational tolerances "A" for the
stroke and deflection apply for current collectors
and conductor system together. They compen-
sate for the difference that results fro m impreci-
sions in the movement of the vehicle and
possible installation offset at the conductor sys-
tem.
Use in deep-freeze warehouse (with special connection cable) on request.
(1)
Use with flat plug connection and/or screw terminal.
(2)
Version with adapter plate and terminal block.
Current collector types
Installation height "H"
[mm]
Stroke and lateral deflection "A"
[mm]
KST 30 to KST 63
85
± 20
KSTU 30 to KSTU 63
85
± 20
KESR 32-55 S-6-14 to 10-14
(1)
88
± 15
KESR 32-55 F-6-14 to 10-14
(1)
88
± 15
KESL 32-63 S-6-14 to 10-14
(1)
105
± 30
KESL 32-55 F-6-14 to 10-14
(1)
105
± 30
KESR 63 S-6-14 HS to 10-14 HS KBL + KBR
(1)(2)
133
± 15
KESL 63 S-6-14 HS to 10-14 HS KBL + KBR
(1)(2)
150
± 30