COMMISSIONING
71
Step 4
Assembly steps:
1. Insert the three hangers into the funnel holes (1)
and slide the funnel onto the conductor rail sec-
tion.
Step 5
Assembly steps:
1. Attach the transfer funnel to the retaining plate
using the VKS hangers.
Step 6
Required tools:
⚒
Screwdriver
Assembly steps:
1. Secure the hangers using the fixed point screws.
Step 7
Assembly steps:
1. Align the funnel unit accurately with the auxiliary
support and fasten it.