Installation and maintenance instructions ecoTEC plus 937 0020031552_06
9 Troubleshooting
9.1
Logical fault finding procedure
Carry out the following checks before the actual trou-
bleshooting:
Carry out the tests to check electrical safety (see
Section "Preparatory Checks on the Electrical Sys-
tem").
Check that the external power supply for the combi
boiler is switched on and that there is a supply volt-
age of 230 V AC between the connections "L" and
"N".
Check that the gas supply to the combi boiler is
switched on.
Check that the combi boiler has been properly purged
and that there is a supply pressure of 20 mbar the
inlet to the boiler. (See Section "Gas Supply".)
Check that the heating system is filled with water and
that there is a pressure of between 1.0 and 1.5 mbar.
Otherwise top up the system and bleed. (See Section
"Filling and bleeding the Heating System".)
Check that the stop valves in the flow and return
lines of the combi boiler are open.
Check that the mains switch is set to "ON".
Set the temperature of the central heating to "Maxi-
mum".
Set the temperature of the hot water preparation to
"Maximum".
Check that all external controllers are switched on
and are demanding heat (if no external controllers
are fitted, the connections 3 and 4 on the combi
boiler terminal must be connected together).
Check that the burner anti-cycling time mode on the
combi boiler is not active.
>
>
>
>
>
>
>
>
>
>
>
9.1.1 Status
codes
The status codes which you can see in the display pro-
vide information concerning the current operating sta-
tus of the unit.
Proceed as follows to display the status codes:
Fig. 9.1 Display of status codes
Press the "
i
" button.
The display shows the status code e.g. “
S.04
” for the
"Burner mode - heating".
The status code display can be de-activated as follows:
Press the "
i
" button or
Do not press any button for about 4 minutes.
The current heating flow temperature appears in the
display again.
>
>
>
>
9 Troubleshooting
Summary of Contents for ecoTEC plus 937
Page 1: ...For the heating engineer Installation and maintenance instructions GB IE ecoTEC plus 937 VUI...
Page 74: ...74 Installation and maintenance instructions ecoTEC plus 937 0020031552_06...
Page 76: ...76 Installation and maintenance instructions ecoTEC plus 937 0020031552_06...
Page 77: ...Installation and maintenance instructions ecoTEC plus 937 0020031552_06 77...
Page 78: ......
Page 79: ......
Page 80: ...0020031552_06 GBIE 102010 Subject to alterations...