4 Set-up
8
Installation and maintenance instructions recoVAIR 0020188110_03
225 cm
60 cm
60 cm
1
0
0
2
2
1
▶
If you install the product in a room with a bath tub, install
it outside the protective areas shown.
225 cm
60 cm
60 cm
1
0
2
2
0
1
▶
If you install the product in a room with a shower tray,
install it outside the protective areas shown.
225 cm
240 cm
120 cm
1
1
▶
If you install the product in a room with a shower, install it
outside the protective areas shown.
4.3.2
Observing the requirements for the
installation site of the remote control (step
switch/control)
▶
Ensure that the remote control is always accessible at
the installation site.
▶
Ensure that there is sufficient space to install and operate
the remote control.
4.3.3
Observe the requirements for silencers and
for installing ducts and the product
If the opening for the exit air pipeline is too close to the inlet
opening of the outside air pipeline, the exit air can recircu-
late.
▶
Prevent exit air from being sucked in directly through
the outside air opening, supply air from being sucked in
directly through the exhaust air opening, and transfer air
from being sucked in directly through areas where there
are leaks/cable feedthroughs.
▶
If the circumstances locally are such that you are unable
to comply with the minimum distance, you must use a
compact façade duct.
▶
If required, connect the product to the pipelines using a
sound-absorbing hose in order to minimise noise pollu-
tion caused by structure-borne noise.
▶
Install silencers in order to minimise noise pollution via
the duct system.
▶
If you install the product in an attic, select an installation
site that is not above living spaces.
▶
If particular acoustic requirements are in place at the
installation site, you should take corresponding on-site
measures to prevent noise.