5 Boiler Installation Sequence 5
Instructions for installation and servicing aquaPLUS VUI 362-7
18
5.11 Electrical installation
General requirements
Important: All electrical work shall be carried out by
a competent person and shall comply with BS7671
(IEE Regulations).
The boiler is supplied for connection to 230 V, ~ 50 Hz
supply fused at 3 A rating.
Connection to the mains supply shall be made via a
fused 3 pin plug to an unswitched shuttered socket,
both complying to the requirements of BS1363.
(Alternatively, connection may be made via a 3 A fused
double pole isolator having a contact separation of at
least 3 mm in all poles and supplying the boiler and
controls only).
The point of connection to the mains supply must allow
complete electrical isolation of the boiler and its
ancillary controls. It should be readily accessible and
adjacent to the boiler. A 3 core flexible cord according
to BS6500 tables 6, 8 or 16 (3 x 0.75 to 3 x 1.5 mm
2
)
should be used.
Warning: This appliance must be earthed.
Important: Ensure that all cords pass through the
cable clamps in the rear of the control box and are
securely fixed. Ensure that the power supply is
connected such that the current carrying conductors
become taut before the earth conductor should the
supply cord slip from the cable clamp.
Note:
DO NOT use boiler terminal connections 7-8-9.
Warning!
Mains connection terminals L and N remain live
even when the boiler on/off control is switched
off.
5.12 Connection to the main supply
• Lower the control panel.
• Unclip the terminal box cover (1) from the control
panel (2).
• Feed the power supply cord in to the appliance as
shown (Fig 5.10).
• Use cable clamps.
• Connect the power supply cord as follows (Fig. 5.11, on
page 20).
Green/yellow (earth) wire boiler terminal Earth sign
Blue (neutral) wire boiler terminal N
Brown (live) wire boiler terminal L
• Refit the terminal box cover by pushing into place
until it clips back into position.
• Raise the control panel and secure in place.
Note:
DO NOT use boiler terminal connections 7-8-9.
Supplied by HeatingSpares247.com