Appendix
26
Installation and maintenance instructions atmoMAG 0020271943_00
MAG 114/1 Z(E-
BE/FR)
MAG 114/1 Z(E-DE)
MAG 114/1 Z(LL-
DE)
MAG 114/1 Z(P-
BE/FR)
CO
₂
content at min. heat output
2.70 %
2.70 %
2.70 %
2.70 %
Max. flue gas mass flow rate
6.40 g/s
6.40 g/s
6.40 g/s
6.40 g/s
Min. flue gas mass flow rate
1.78 g/s
1.78 g/s
1.78 g/s
1.78 g/s
MAG 144/1 Z(E-BE)
MAG 144/1 Z(E-DE)
MAG 144/1 Z(LL-
DE)
MAG 144/1 Z(P-BE)
Gas flow rate at max. heat output
2.92 m
³
/h
2.92 m
³
/h
2.92 m
³
/h
2.92 m
³
/h
Gas connection pressure
1.7 … 2.5 kPa
(17.0 … 25.0 mbar)
1.7 … 2.5 kPa
(17.0 … 25.0 mbar)
1.7 … 2.5 kPa
(17.0 … 25.0 mbar)
1.7 … 2.5 kPa
(17.0 … 25.0 mbar)
Number of burner jets
28
28
28
28
Burner jet
0.85 mm
0.85 mm
0.85 mm
0.85 mm
Burner pressure
1.38 kPa
(13.80 mbar)
1.38 kPa
(13.80 mbar)
1.38 kPa
(13.80 mbar)
1.38 kPa
(13.80 mbar)
Air requirement for combustion at
max. heat input
50.24 m
³
/h
50.24 m
³
/h
50.24 m
³
/h
50.24 m
³
/h
Air requirement for combustion at
min. heat input
40.55 m
³
/h
40.55 m
³
/h
40.55 m
³
/h
40.55 m
³
/h
CO
₂
content at max. heat output
6.20 %
6.20 %
6.20 %
6.20 %
CO
₂
content at min. heat output
2.60 %
2.60 %
2.60 %
2.60 %
Max. flue gas mass flow rate
10.53 g/s
10.53 g/s
10.53 g/s
10.53 g/s
Min. flue gas mass flow rate
2.99 g/s
2.99 g/s
2.99 g/s
2.99 g/s
Technical data
–
Natural gas G25
Applicability:
Germany
MAG 114/1 Z(E-DE)
MAG 114/1 Z(LL-
DE)
MAG 144/1 Z(E-DE)
MAG 144/1 Z(LL-
DE)
Gas flow rate at max. heat output
2.67 m
³
/h
2.67 m
³
/h
3.36 m
³
/h
3.36 m
³
/h
Gas connection pressure
1.8 … 2.5 kPa
(18.0 … 25.0 mbar)
1.8 … 2.5 kPa
(18.0 … 25.0 mbar)
1.8 … 2.5 kPa
(18.0 … 25.0 mbar)
1.8 … 2.5 kPa
(18.0 … 25.0 mbar)
Number of burner jets
24
24
28
28
Burner jet
1.00 mm
1.00 mm
1.02 mm
1.02 mm
Burner pressure
0.97 kPa
0.97 kPa
1.05 kPa
1.05 kPa
Air requirement for combustion at
max. heat input
36.95 m
³
/h
36.95 m
³
/h
50.06 m
³
/h
50.06 m
³
/h
Air requirement for combustion at
min. heat input
30.00 m
³
/h
30.00 m
³
/h
39.73 m
³
/h
39.73 m
³
/h
CO
₂
content at max. heat output
6.50 %
6.50 %
6.10 %
6.10 %
CO
₂
content at min. heat output
2.70 %
2.70 %
2.60 %
2.60 %
Max. flue gas mass flow rate
7.46 g/s
7.46 g/s
12.83 g/s
12.83 g/s
Min. flue gas mass flow rate
2.13 g/s
2.13 g/s
3.58 g/s
3.58 g/s
Technical data
–
Natural gas G25
Applicability:
Belgium
MAG 114/1 Z(E-
BE/FR)
MAG 114/1 Z(P-
BE/FR)
MAG 144/1 Z(E-BE)
MAG 144/1 Z(P-BE)
Gas flow rate at max. heat output
2.50 m
³
/h
2.50 m
³
/h
3.17 m
³
/h
3.17 m
³
/h
Gas connection pressure
2.0 … 3.0 kPa
(20.0 … 30.0 mbar)
2.0 … 3.0 kPa
(20.0 … 30.0 mbar)
2.0 … 3.0 kPa
(20.0 … 30.0 mbar)
2.0 … 3.0 kPa
(20.0 … 30.0 mbar)
Number of burner jets
24
24
28
28
Burner jet
0.85 mm
0.85 mm
0.85 mm
0.85 mm
Burner pressure
14.8 mbar
14.8 mbar
18.5 mbar
18.5 mbar
Air requirement for combustion at
max. heat input
39.9 m
³
/h
39.9 m
³
/h
52.5 m
³
/h
52.5 m
³
/h