Appendix
0020271943_00 atmoMAG Installation and maintenance instructions
27
MAG 114/1 Z(E-
BE/FR)
MAG 114/1 Z(P-
BE/FR)
MAG 144/1 Z(E-BE)
MAG 144/1 Z(P-BE)
Air requirement for combustion at
min. heat input
31.1 m
³
/h
31.1 m
³
/h
41.6 m
³
/h
41.6 m
³
/h
CO
₂
content at max. heat output
5.67 %
5.67 %
5.50 %
5.50 %
CO
₂
content at min. heat output
2.60 %
2.60 %
2.47 %
2.47 %
Max. flue gas mass flow rate
7.65 g/s
7.65 g/s
12.77 g/s
12.77 g/s
Min. flue gas mass flow rate
2.21 g/s
2.21 g/s
3.74 g/s
3.74 g/s
Technical data
–
Liquid gas G31
MAG 114/1 Z(E-
BE/FR)
MAG 114/1 Z(E-DE)
MAG 114/1 Z(LL-
DE)
MAG 114/1 Z(P-
BE/FR)
Gas flow rate at max. heat output
1.69 kg/h
1.69 kg/h
1.69 kg/h
1.69 kg/h
Gas connection pressure at max.
heat output
2.5 … 4.5 kPa
(25.0 … 45.0 mbar)
4.25 … 5.75 kPa
(42.50
… 57.50 mbar)
4.25 … 5.75 kPa
(42.50
… 57.50 mbar)
2.5 … 4.5 kPa
(25.0 … 45.0 mbar)
Number of burner jets
24
24
24
24
Burner jet
0.5 mm
0.5 mm
0.5 mm
0.5 mm
Burner pressure
31.7 mbar
31.7 mbar
31.7 mbar
31.7 mbar
Air requirement for combustion at
max. heat input
38.3 m
³
/h
38.3 m
³
/h
38.3 m
³
/h
38.3 m
³
/h
Air requirement for combustion at
min. heat input
28.9 m
³
/h
28.9 m
³
/h
28.9 m
³
/h
28.9 m
³
/h
CO
₂
content at max. heat output
7.30 %
7.30 %
7.30 %
7.30 %
CO
₂
content at min. heat output
3.30 %
3.30 %
3.30 %
3.30 %
Max. flue gas mass flow rate
4.13 g/s
4.13 g/s
4.13 g/s
4.13 g/s
Min. flue gas mass flow rate
1.10 g/s
1.10 g/s
1.10 g/s
1.10 g/s
MAG 144/1 Z(E-BE)
MAG 144/1 Z(E-DE)
MAG 144/1 Z(LL-
DE)
MAG 144/1 Z(P-BE)
Gas flow rate at max. heat output
2.15 kg/h
2.15 kg/h
2.15 kg/h
2.15 kg/h
Gas connection pressure at max.
heat output
2.5 … 4.5 kPa
(25.0 … 45.0 mbar)
4.25 … 5.75 kPa
(42.50
… 57.50 mbar)
4.25 … 5.75 kPa
(42.50
… 57.50 mbar)
2.5 … 4.5 kPa
(25.0 … 45.0 mbar)
Number of burner jets
28
28
28
28
Burner jet
0.51 mm
0.51 mm
0.51 mm
0.51 mm
Burner pressure
34.5 mbar
34.5 mbar
34.5 mbar
34.5 mbar
Air requirement for combustion at
max. heat input
49.84 m
³
/h
49.84 m
³
/h
49.84 m
³
/h
49.84 m
³
/h
Air requirement for combustion at
min. heat input
38.04 m
³
/h
38.04 m
³
/h
38.04 m
³
/h
38.04 m
³
/h
CO
₂
content at max. heat output
7.15 %
7.15 %
7.15 %
7.15 %
CO
₂
content at min. heat output
3.20 %
3.20 %
3.20 %
3.20 %
Max. flue gas mass flow rate
6.82 g/s
6.82 g/s
6.82 g/s
6.82 g/s
Min. flue gas mass flow rate
1.84 g/s
1.84 g/s
1.84 g/s
1.84 g/s