2 Notes on the documentation
6
Installation and maintenance instructions atmoMAG 0020271943_00
2
Notes on the documentation
2.1
Observing other applicable documents
▶
You must observe all the operating and installation in-
structions included with the system components.
2.2
Storing documents
▶
Pass these instructions and all other applicable docu-
ments on to the system operator.
2.3
Validity of the instructions
These instructions apply only to:
Product article number
Applicability:
Germany
OR Belgium
MAG 114/1 Z(E-
BE/FR)
Belgium
0010022555
MAG 114/1 Z(E-DE)
Germany
0010022556
MAG 114/1 Z(LL-
DE)
Germany
0010022557
MAG 114/1 Z(P-
BE/FR)
Belgium
0010022554
MAG 144/1 Z(E-BE)
Belgium
0010022544
MAG 144/1 Z(E-DE)
Germany
0010022562
MAG 144/1 Z(LL-
DE)
Germany
0010022563
MAG 144/1 Z(P-BE)
Belgium
0010022546
3
Product description
3.1
Information on the data plate
The data plate is mounted at the front of the down-draught
diverter, under the product casing, at the factory.
Applicability:
Belgium
OR Germany
Information on the
data plate
Meaning
MAG
Product category
11/14
Power in l/min
-4/1
Chimney connection/product generation
Z
With Piezo ignition
atmoMAG
Product series
Type B11 BS
Approved gas boiler types
Cat I
Cat II
Single-gas unit
Multiple gas type boiler
2E+ (BE)
3P (BE)
2ELL 3P (DE)
Permissible gas categories
G20/25/31
Permitted gas types with connection
pressures
P
nom.
Maximum heat output
P
min.
Minimum heat output
Q
nom.
Maximum heat input
Information on the
data plate
Meaning
Q
min.
Minimum heat input
P
w max.
Maximum permissible water pressure
Serial number
7th to 16th digit = product article number
3.2
Product design
Applicability:
MAG 114/1 Z(E-BE/FR)
OR MAG 114/1 Z(E-DE)
OR MAG 114/1 Z(LL-DE)
OR MAG 114/1 Z(P-BE/FR)
1
2
4
3
5
6
7
8
9
10
12
11
1
Down-draught diverter
2
Flue gas sensor
3
Safety cut-out
4
Heat exchanger
5
Burner
6
Flow rate se-
lector/temperature
selector
7
Gas valve assembly
8
Rotary power switch
9
Piezo igniter
10
Ignition electrode
11
Thermocouple
12
Pilot burner