Appendix
0020230535_05 ecoFIT pure Installation and maintenance instructions
41
I
Technical data
Technical data
–
Heating
VU 126/6-3 OV (H-
GB)
VU 156/6-3 OV (H-
GB)
VU 186/6-3 OV (H-
GB)
VU 256/6-3 OV (H-
GB)
Max. flow temperature adjustment
range (default setting: 75 °C)
10 … 80
℃
10 … 80
℃
10 … 80
℃
10 … 80
℃
Maximum permissible pressure
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Nominal water flow (
Δ
T = 20 K)
530 l/h
655 l/h
788 l/h
1,094 l/h
Nominal water flow (
Δ
T = 30 K)
353 l/h
436 l/h
525 l/h
729 l/h
Approximate value for the
condensate volume (pH value
between 3.5 and 4.0) at 50/30 °C
1.23 l/h
1.53 l/h
1.84 l/h
2.55 l/h
VU 306/6-3 OV (H-
GB)
VU 356/6-3 OV (H-
GB)
Max. flow temperature adjustment
range (default setting: 75 °C)
10 … 80
℃
10 … 80
℃
Maximum permissible pressure
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Nominal water flow (
Δ
T = 20 K)
1,313 l/h
1,535 l/h
Nominal water flow (
Δ
T = 30 K)
876 l/h
1,023 l/h
Approximate value for the
condensate volume (pH value
between 3.5 and 4.0) at 50/30 °C
3.06 l/h
3.65 l/h
Technical data
–
G20 power/loading G20
VU 126/6-3 OV (H-
GB)
VU 156/6-3 OV (H-
GB)
VU 186/6-3 OV (H-
GB)
VU 256/6-3 OV (H-
GB)
Maximum heat output
12 kW
15 kW
18 kW
25 kW
Effective output range (P)
at 40/30 °C
4.8 … 13.0 kW
4.8 … 16.2 kW
5.3 … 19.5 kW
6.5 … 27.0 kW
Effective output range (P)
at 50/30 °C
4.7 … 12.8 kW
4.7 … 15.9 kW
5.2 … 19.1 kW
6.4 … 26.5 kW
Effective output range (P)
at 80/60 °C
4.5 … 12.3 kW
4.5 … 15.2 kW
5.0 … 18.3 kW
6.1 … 25.4 kW
Domestic hot water heat
output (P)
4.4 … 15.0 kW
4.4 … 18.0 kW
4.9 … 25.2 kW
6.0 … 30.0 kW
Maximum heat input
–
heating (Q max.)
12.3 kW
15.3 kW
18.4 kW
25.5 kW
Minimum heat input
–
heat-
ing (Q min.)
4.5 kW
4.5 kW
5.0 kW
6.1 kW
Maximum heat input
–
hot
water (Q max.)
15.3 kW
18.4 kW
25.7 kW
30.6 kW
Minimum heat input
–
hot
water (Q min.)
4.5 kW
4.5 kW
5.0 kW
6.1 kW
VU 306/6-3 OV (H-
GB)
VU 356/6-3 OV (H-
GB)
Maximum heat output
30 kW
35 kW
Effective output range (P)
at 40/30 °C
7.6 … 32.4 kW
7.6 … 37.8 kW
Effective output range (P)
at 50/30 °C
7.4 … 31.8 kW
7.0 … 35.8 kW
Effective output range (P)
at 80/60 °C
7.1 … 30.5 kW
7.2 … 34.8 kW
Domestic hot water heat
output (P)
7.0 … 35.0 kW
7.1 … 35.0 kW
Maximum heat input
–
heating (Q max.)
30.6 kW
35.7 kW