8
Installation and maintenance instructions ecoTEC exclusive 0020193966_04
3
Technical data
Technical data
–
General
VU 256/5
‑
7
(H-GB)
ecoTEC
exclusive 627
Designated country (des-
ignation in accordance
with ISO 3166)
GB (United
Kingdom)
Approved unit categories
II
2H3P
Gas connection, boiler
side
15 x 1.0 mm
Flow/return heating con-
nections, boiler side
22 x 1.5 mm
Expansion relief valve
connector (min.)
15 mm
Air/flue gas connection
60/100 mm
Condensate drain pipe-
work (min.)
19 mm
Gas connection pressure,
G20 natural gas
2.0 kPa
(20.0 mbar)
Gas connection pressure,
G31 propane
3.7 kPa
(37.0 mbar)
Gas flow rate at 15 °C
and 1013 mbar (based on
hot water generation, if
applicable), G20
3.2 m
³
/h
Gas flow rate at 15 °C
and 1013 mbar (based on
hot water generation, if
applicable), G31
2.35 kg/h
Min. flue gas mass rate
(G20)
1.47 g/s
Min. flue gas mass rate
(G31)
1.81 g/s
Max. flue gas mass rate
13.60 g/s
Min. flue gas temperature
40
℃
Max. flue gas temperat-
ure
65
℃
Approved gas-fired units
C13, C33,
C53
30% efficiency
108.3 %
NOx class
6
Test symbol/registration
no.
CE
‑
0085CM0320
Device Specific Number
(DSN)
209
SAP 2009/2012 annual
efficiency (%)
89.6 %
Boiler dimension, width
440 mm
Boiler dimension, height
720 mm
Boiler dimension, depth
338 mm
Mounting weight
37.5 kg
Operating weight (with
water)
39.0 kg
Technical data
–
G20 power/loading G20
* The lowest nominal heat output may be higher than the
value in the technical data, depending on the design of the
system and the current operating status.
VU 256/5
‑
7
(H-GB)
ecoTEC
exclusive 627
Nominal heat output
range P at 50/30 °C *
3.4 to 26.7 kW
Nominal heat output
range P at 80/60 °C *
3.0 to 24.7 kW
Maximum heat output for
hot water generation
30.0 kW
Maximum heat input for
hot water generation
30.3 kW
Maximum heat input,
heating side
25.3 kW
Minimum heat input
3.3 kW
Heating adjustment range
3 to 26 kW
Technical data
–
Power/loading G31
* The lowest nominal heat output may be higher than the
value in the technical data, depending on the design of the
system and the current operating status.
VU 256/5
‑
7
(H-GB)
ecoTEC
exclusive 627
Nominal heat output
range P at 50/30 °C *
4.2 to 26.7 kW
Nominal heat output
range P at 80/60 °C *
3.7 to 24.7 kW
Maximum heat output for
hot water generation
30.0 kW
Maximum heat input for
hot water generation
30.3 kW
Maximum heat input,
heating side
25.3 kW
Minimum heat input
4.0 kW
Technical data
–
Heating
VU 256/5
‑
7
(H-GB)
ecoTEC
exclusive 627
Maximum flow temperat-
ure
85
℃
Max. flow temperature
adjustment range (default
setting: 75 °C)
30 to 80
℃
Permissible total over-
pressure
0.25 MPa
(2.50 bar)
Minimum pressure for
full operation
0.08 MPa
(0.80 bar)
Expansion vessel capa-
city
10 l
Circulation water volume
(with reference to
Δ
T= 20 K)
1,064 l/h
Approx. condensate rate
(pH value 3.5 to 4.0) in
50/30 °C heating mode
2.52 l/h
Remaining feed head of
pump (at nominal circula-
tion water volume)
0.020 MPa
(0.200 bar)