0020193966_04 ecoTEC exclusive Installation and maintenance instructions
11
6
Set-up
6.1
Scope of delivery
Check that the scope of delivery is complete and intact.
Num-
ber
Designation
1
Heat generator
1
Installation kit containing the following:
1
- Product bracket
1
- Expansion relief valve connection pipe
1
- Gas stopcock
1
- Gas connection pipe, dia. 15 mm
2
- Service valve
2
- Heating flow/return connection pipe
3
- Bag with small parts
1
- Gas family coding resistor
1
Condensate discharge hose
1
Mounting template
1
Enclosed documentation
6.2
Dimensions
620
20
720
A
B
125
180
130
440
80
188
160
100
100
55
55
12
1
3
4
5
3
5
11
4
6
7
8
9
2
10
1
Air/flue pipe wall duct
2
Unit mounting bracket
3
Heating flow
4
Gas connection
5
Heating return
6
Connection for the
heating expansion relief
valve drain pipework
7
Condensate siphon
connection
8
Condensate siphon
9
Cylinder return
10
Cylinder flow
11
R1 tundish/condensate
siphon connection
12
Air/flue pipe connection
Consult the installation template that is supplied to find the
dimension A.
The product's installation depth B can be found in the tech-
nical data in the appendix.