0020193966_04 ecoTEC exclusive Installation and maintenance instructions
41
13.7.8 Replacing the all-gas sensor
3
2
1
1.
Remove the air intake pipe; see Removing the compact
thermal module (
2.
Undo the screws
(3)
just enough so that you can pull
out the all-gas sensor
(1)
by the cable.
3.
Remove the plug
(2)
by pushing in the latching lug.
4.
Reinstall the new all-gas sensor in the reverse order.
13.8
Completing repair work
1.
Establish the power supply.
2.
Switch the product back on if this has not yet been
done. (
3.
Install the front casing.
4.
Open all service valves and the gas stopcock.
13.9
Checking the product for leak-tightness
▶
Check that the product is leak-tight. (
14 Decommissioning
14.1
Temporarily decommissioning the product
▶
Press the on/off button.
◁
The display goes out.
▶
Close the gas stopcock.
▶
For products with domestic hot water generation and
products with a connected domestic hot water cylinder,
you must also close the cold-water isolation valve.
14.2
Permanently decommissioning the product
▶
Press the on/off button.
◁
The display goes out.
▶
Disconnect the product from the power grid.
▶
Close the gas stopcock.
▶
Close the cold-water isolation valve.
▶
Drain the product. (
15 Recycling and disposal
Disposing of the packaging
▶
Dispose of the packaging correctly.
▶
Observe all relevant regulations.
▶
For detailed information refer to www.vaillant.co.uk.