0020193966_04 ecoTEC exclusive Installation and maintenance instructions
45
Setting level
Values
Unit
Increment, select, explanation
Default
setting
Min.
Max.
Accessory relay 1
1
10
–
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2
Accessory relay 2
1
10
–
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
2
Set the type of gas
0
2
–
0: Natural gas
1: Propane 50 mbar
2: Propane 30/37 mbar
–
Contact details
Phone number
–
0-9
–
End the installation assistant?
–
–
–
Yes, No
–
¹
Fault lists are only displayed, and can only be deleted, if faults have occurred.
C
Overview of diagnostics codes
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Code
Parameter
Values
Unit
Increment, select, explanation
Factory
setting
Own
setting
Min.
Max.
D.000
Heating partial load
Output-range-
specific
kW
Adjustable partial heat load
Auto: Product automatically adjusts
max. partial load to current system
demand
Auto
D.001
Pump overrun: Heating
1
60
min
Overrun time of internal heating
pump for heating mode
1
5
D.002
Max. anti-cycl. time: Heat-
ing
2
60
min
Max. burner anti-cycling time heat-
ing at 20 °C flow temperature
1
20
D.003
Outlet temperature actual
value
Current value
°C
–
–
Not ad-
justable
D.004
Cylinder temperature ac-
tual value
Current value
°C
Measured value of domestic hot
water sensor
–
Not ad-
justable
D.005
Heating target flow temper-
ature
Current value
°C
Target flow temperature value (or
target return value)
–
Not ad-
justable
D.006
Outlet temperature target
value
Current value
°C
Domestic hot water temperature
target value (only products with in-
tegrated domestic hot water gener-
ation)
–
Not ad-
justable