0020193966_04 ecoTEC exclusive Installation and maintenance instructions
55
F
Check programmes
–
Overview
Check programme
Meaning
P.00 Purging
The internal pump is cyclically actuated. The heating circuit and domestic hot water circuit are purged
adaptively by automatically switching the circuits via the automatic air vent (the cap for the automatic
air vent is loosened at the factory).
DHW circuit active
or
Heating circuit active
display.
once:
Start purging.
once (
Cancel
): End purge programme.
Note:
The duration of the purge programme
is displayed using a countdown. The programme then ends.
P.01 Maximum load
After successful ignition, the product is operated at maximum heat input.
P.02 Minimum load
After successful ignition, the product is operated at minimum heat input.
P.04 Reset eGas
Calling up the programme deletes all of the CH offsets (central heating) that have been saved from
previous calibration processes. The products then starts by fully calibrating the combustion regulation
(status S.09).
P.06 Filling mode
The prioritising diverter valve is moved to the mid-position. The burner and pump are switched off (to
fill or drain the product).
G
Function menu
–
Overview
Function menu
Meaning
T.01 Internal pump
The internal pump is switched on and off.
T.02 3-way valve
The prioritising diverter valve is moved to the heating or domestic hot water position.
T.03 Fan
The fan is switched on and off. The fan runs at maximum rotational speed.
T.04 Cylinder charging pump
The cylinder charging pump is switched on and off.
T.05 Circulation pump
The circulation pump is switched on and off.
T.06 External pump
The external pump is switched on and off.
T.08 Burner
The product starts up and switches to minimum load. The flow temperature is shown in the display.