0020193966_04 ecoTEC exclusive Installation and maintenance instructions
9
Technical data
–
Electrics
VU 256/5
‑
7
(H-GB)
ecoTEC
exclusive 627
Electric connection
230 V/50 Hz
Permissible connected
voltage
190 to 253 V
Built-in fuse (slow-blow)
2 A
Min. electrical power con-
sumption
28 W
Max. electrical power
consumption for heat-
ing mode (nominal heat
loading)
62 W
Max. electrical power
consumption for cylinder
charging
80 W
Standby electrical power
consumption
< 1.9 W
Level of protection
IP X4 D
4
Notes on the documentation
▶
Always observe all operating instructions enclosed with
the installation components.
▶
Store these instructions and all other applicable docu-
ments for further use.
These instructions apply only to:
Product article number
Article num-
ber
Gas Council
Number
VU 256/5
‑
7 (H-GB)
ecoTEC exclusive 627
0010017063
41-694-02
5
Product description
5.1
CE marking
The CE marking shows that the products comply with the
basic requirements of the applicable directives as stated on
the declaration of conformity.
The declaration of conformity can be viewed at the manufac-
turer's site.
5.2
Energy Saving Trust Endorsed Products
Only the most energy efficient products can carry the
‘Energy Saving Trust Endorsed Product’ brandmark making
it easy for consumers to choose products that have met strict
energy performance criteria.
Available for: Boilers, Heating controls and chemical inhib-
itors, the Energy Saving Trust endorsed product brandmark
gives consumers confidence that a product will cost less to
run, help lower energy bills and reduce carbon emissions.
About the Energy Saving Trust
Energy Saving Trust is an independent and impartial organ-
isation that provides trusted energy saving advice to em-
power millions of people to lead affordable, low energy life-
styles. For more information visit energysavingtrust.org.uk
5.3
Hot Water Association
Vaillant is a full member of the Hot Water Association and
promotes the scheme in association with its cylinder range.
Details are available on the web site www.vaillant.co.uk
5.4
Information on the identification plate
The identification plate is mounted on the underside of the
product in the factory.
Information on the
identification plate
Meaning
Read the instructions.
VU(W) ...
Type designation
..6/5-7
Calorific value power/product generation
equipment
ecoTEC exclusive
Product description
2H, G20
–
20 mbar
(2.0 kPa)
Gas group and gas connection pressure
as set at the factory
ww/yyyy
Date of manufacture: Week/year
Cat.
Approved unit categories
Types
Approved gas-fired units
PMS
Permissible total overpressure in heating
mode
PMW
Permissible total overpressure during hot
water generation
T
max.
Max. flow temperature
ED 92/42
Current efficiency directive fulfilled with
4* rating
V Hz
Mains voltage and mains frequency
W
Max. electrical power consumption
IP
Level of protection
Heating mode
Hot water generation