Operating instructions ecoTEC plus 937
2
Contents
Appliance characteristics ......................................... 2
Recommended accessories ....................................... 2
1
Notes on the documentation ......................... 3
1.1
Storage of the documents ....................................3
1.2 Symbols
used
...........................................................3
1.3
Validity of the instruction manual ......................3
1.4 CE
label
......................................................................3
1.5 Identification
plate
..................................................3
2 Safety
...............................................................4
2.1 Setup and adjustment ............................................4
2.2
Action in case of emergency ................................4
2.3 Safety
instructions
..................................................4
2.4
Modifications to the boiler and its
environment .............................................................4
2.5 Setup and adjustment ............................................4
3
Instructions on operation .............................. 5
3.1 Factory
guarantee
...................................................5
3.1.1
Two years guarantee for ecoTEC plus units .....5
3.1.2 Registering
with
us
.................................................5
3.1.3 Immediate
help
........................................................5
3.2 Intended
use
.............................................................5
3.3
Care ............................................................................6
3.4
Recycling and disposal ...........................................6
3.4.1 Equipment
.................................................................6
3.4.2 Packaging
..................................................................6
4 Operation
......................................................... 6
4.1
Overview of the operating elements ..................6
4.2
Measures prior to commissioning .......................8
4.2.1 Opening the isolating valves ................................8
4.2.2 Checking system pressure ....................................8
4.3 Start-up
......................................................................9
4.4
Domestic hot water operation .............................9
4.4.1 Setting the hot water temperature .....................9
4.4.2 Switching on/off the warmstart function ........ 10
4.4.3 Storage tank charging mode .............................. 10
4.4.4 Drawing off the hot water .....................................11
4.5 Heating
operation
...................................................11
4.5.1 Setting the flow temperature ...............................11
4.5.2 Switching heating mode off (summer mode) ..12
4.5.3 Setting a room thermostat or weather
compensator ............................................................12
4.6
Status displays (for maintenance and
servicing by the engineer) ...................................12
4.7
Troubleshooting ......................................................13
4.7.1
Faults caused by water pressure too low .........13
4.7.2 Faults
in
ignition
.....................................................13
4.7.3 Faults in the air/flue gas routing ........................13
4.8 De-commissioning
................................................. 14
4.9 Frost
protection
..................................................... 14
4.10 Maintenance and customer service .................. 14
Appliance characteristics
The Vaillant ecoTEC plus 937 is a compact gas wall-
mounted boiler with condensing technology and 15 litre
laminar stainless steel storage tank.
The Vaillant ecoTEC plus 937 provides central heating
and hot water, whereby the hot water is supplied direct
from the boiler. Hot water provision takes place
automatically when the hot water tap is opened. This
involves automatic control of the boiler so that the
demand for heating and hot water is automatically
covered in the most economic way.
Recommended accessories
Vaillant have a range of control accessories that can
either push-fit into the boiler fascia or be wall mounted.
Controller
Item no.
VRC 400 (1-circuit controller, weather-
controlled)
00 2001 0843
VRT 360 (room temperature controller)
00 2001 0842
VRT 360f (room temperature controller)
00 2001 8258
VRT 230 (room temperature controller)
00 2001 0841
timeSWITCH 140 (timer)
306 760
timeSWITCH 130 (timer)
306 759
VRT 30 (room thermostat)
300 637
VRT 30 (room thermostat)
0020018265
Telecommunication
Item no.
vrnetDIALOG 830 (Int)
00 2000 3988
vrnetDIALOG 860/2 (Int)
00 2000 3984
Accessories
Item no.
VR 65 control centre for UK cylinder
installation (eBUS)
307 215
vrDIALOG 810/2
00 2002 3370
Table Controller options
Your expert technician will help you with selection of the
suitable controller.
Contents
Appliance characteristics
Recommended accessories
Summary of Contents for ecoTEC plus 937
Page 15: ...20 C 20 C C 5 5 C bar bar VRT VRC i F P...
Page 16: ...0020031573_00 GB 022007...