Set-up 5
0020200969_07 Set-up instructions
21
5.4.4
Variable terminal set (VTK) (not for
0010035512)
5.4.4.1 Scope of delivery
1
2
3
4
1
87° elbow (2 x)
2
Pipe clamps (3 x)
3
Extension (1 m) without
sleeve
4
Extension (1 m) with
sleeve
–
Variable terminal set, black, article number 0020219529
–
Variable terminal set, white, article number 0020219530
5.4.4.2 Installing the variable terminal set (VTK)
A
B
1.
Release the catch between the opening piece and the
end pipe.
2.
Pull the end pipe from the opening piece.
0°
3.
Slide the first 87° elbow onto the opening piece until
you hear the 87° elbow click into place.
5.4.4.3 Installing extensions
1.
Install the flue system from the 87° elbow to the flue
outlet.
–
Begin with the extension with the sleeve. To be able
to install the second 87° elbow with the end pipe,
you must install the extension without a sleeve last.
–
Allow expansion space of 1 cm in each sleeve.
–
Ensure that all pipe joints are absolutely leak-tight.
100
80-100
2.
Secure the extensions to the wall using the pipe
clamps.
–
Use one pipe clamp for each extension directly be-
side the sleeve.
–
Upstream of each elbow, install another pipe clamp
on the extension.