Set-up 5
0020200969_07 Set-up instructions
23
5.4.5.2 Installing the wall duct
150-155
15
3°
1
1.
Drill a hole.
–
Diameter: 130 mm
2.
Insert the air/flue pipe
(1)
into the wall opening.
3.
Secure the air/flue pipe with mortar and leave the mor-
tar to harden.
4.
Install the wall collar on the inside and outside of the
wall.
5.4.5.3 Installing the roof duct
150-155
15
3°
1
▶
Insert the air/flue pipe
(1)
without the external collar into
the dormer.
5.4.5.4 Connecting the product
7
6
5
1
2
3
4
1.
Install the product
(4)
–
see the installation instructions
for the product.
2.
If required, replace the connector for the air/flue pipe
(3)
, see the installation instructions for the product.
3.
Connect the connection elbow
(2)
to the connector for
the air/flue pipe
(3)
.
4.
Insert the sliding sleeve
(5)
with the sleeve as far as it
will go in the wall/roof duct
(7)
or the extension
(6)
.
5.
If required, install the extensions .
6.
Connect the sliding sleeve to the connection elbow.
7.
Install the air pipe clamp
(1)
for the sliding sleeve.
8.
Alternatives 1:
Condition
: Wall/roof duct without extension
▶
Install the sliding sleeve. (
8.
Alternatives 2:
Condition
: Wall/roof duct with extension
▶
Install the extensions. (
▶
Install the 45° elbow. (
▶
Install the 87° elbow. (
▶
Install the sliding sleeve. (
▶
Connect all of the pipe joints with air pipe clamps.
(
5.5
Installing the vertical roof duct
5.5.1
Installation instructions
Danger!
Risk of poisoning due to escaping flue
gas and risk of material damage due to the
roof duct shearing off.
Snow and ice sliding down pitched roofs may
break off the vertical roof duct where it exits
the roof.
▶
In regions where heavy snow
falls/extensive ice formation can be ex-
pected, install the vertical roof duct close
to the ridge or install a snow guard mesh
above the roof duct.
The vertical roof ducts can be shortened under the roof.
However, to ensure that the fixing bracket is secured tightly,
the lengths must still be sufficient.
▶
Shorten the flue pipe and the air pipe by the same
amount.
5.5.2
Installing the vertical roof duct, 60/100 mm
diameter
5.5.2.1 Assembling the vertical roof duct
Note
In its as-delivered condition, the lower pipe of the
vertical roof duct is pushed into the upper pipe.