5 Set-up
32
Set-up instructions 0020200969_07
5.7.3.2 Installing the 45° elbow, 60/100 mm diameter
C
A
B
10
10
A
Offset
B
Length of the air pipe
C
Height
1.
Measure the offset
(A)
, e.g. with 300 mm.
Table of offset dimensions (
2.
Use this value from the table to determine the length of the air pipe
(B)
= 284 mm and the height
(C)
= 420 mm.
◁
From that, the corresponding flue pipe length is calculated as 284 + 40 = 324 mm.
Offset
Length of
the air pipe
Height
Offset
Length of
the air pipe
Height in
Offset
Length of
the air pipe
Height in
90
0
210
325
320
445
525
602
645
95
0
215
330
327
450
530
610
650
100
0
220
335
334
455
535
617
655
> 105 to <
155
not possible
not possible
340
341
460
540
624
660
345
348
465
545
631
665
350
355
470
550
638
670
355
362
475
555
645
675
160
86
280
360
369
480
560
652
680
165
93
285
365
376
485
565
659
685
170
100
290
370
383
490
570
666
690
175
107
295
375
390
595
575
673
695
180
115
300
380
397
500
580
680
700
185
122
305
385
404
505
585
687
705
190
129
310
390
412
510
590
694
710
195
136
315
395
419
515
595
701
715
200
143
320
400
426
520
600
709
720
205
150
325
405
433
525
605
716
725
210
157
330
410
440
530
610
723
730
215
164
335
415
447
535
615
730
735
220
171
340
420
454
540
620
737
740
225
178
345
425
461
545
625
744
745
230
185
350
430
468
550
630
751
750
235
192
355
435
475
555
635
758
755
240
199
360
440
482
560
640
765
760
245
206
365
445
489
565
645
772
765
250
214
370
450
496
570
650
779
770
255
221
375
455
503
575
655
786
775
260
228
380
460
511
580
660
793
780
265
235
385
465
519
585
665
800
785