Set-up 5
0020200969_07 Set-up instructions
29
A
5
5
6
7
1
21
2
3
4
1.
Slide the sliding sleeve
(2)
onto the flue pipe
(1)
as far
as it goes.
2.
Pull the sliding sleeve
(2)
back far enough from the flue
pipe
(1)
so that the inserting end of the sliding sleeve
sits in the sleeve
(3)
of the flue pipe
(4)
.
80/125 mm diameter
A
82-90 mm
3.
Connect the air pipes
(5, 7)
with the air pipe clamp
(6)
.
4.
Use a locking screw to secure both sides. (
5.7.2
Installing extensions
Danger!
Risk of poisoning due to escaping flue
gas.
The flue pipes of the air/flue pipe may move
as a result of thermal expansion and may
then become disconnected.
▶
Lock the flue pipe in the spacer of the air
pipe.
5.7.2.1 Installing 60/100 mm diameter extensions
1
2
3
4
1.
Turn the flue pipe
(1)
to a position that enables the
ridge
(2)
on the plastic pipe to be pushed through the
spacer
(4)
.
2.
Pull the pipe quickly and firmly over the detent.
1.
2.
A
B
+ 40 mm
13
70
27
1
2
2
1
3.
First, measure the required air pipe length*
(A)
and
then calculate from that the corresponding flue gas pipe
length
(B)
in each case:
–
Length of the flue pipe: Length of the air
pipe + 40 mm
–
Minimum length of air-pipe extension: 80 mm.
4.
Shorten the pipes, e.g. with a saw.
5.
After shortening it, lock the flue pipe
(1)
inside the air
pipe
(2)
again: Push the flue pipe back into the air pipe.
Turn the flue pipe as far as it will go.
5.7.2.2 Installing 80/125 mm diameter extensions
(PP)
1
2
3
4
1.
Turn the flue pipe
(1)
to a position that enables the
ledges
(3)
on the plastic pipe to be pushed through the
spacer
(4)
.
2.
Pull the flue pipe out of the air pipe
(2)
.
1.
2.
A
B
+ 40 mm
15
70
25
1
2
2
1
3.
First, measure the required air pipe length*
(A)
and then
calculate from that the corresponding flue pipe length
(B)
in each case:
–
Length of the flue pipe: Length of the air
pipe + 40 mm
–
* Minimum length of air-pipe extension: 100 mm.
4.
Cut the pipes with a saw, tin snips, etc.
5.
After shortening, lock the flue pipe
(1)
inside the air pipe
(2)
again.