Set-up 4
0020261188_00 ecoTEC plus Installation and maintenance instructions
7
Information on the
data plate
Meaning
Serial number
For quality control purposes; 3rd and 4th
digits = year of production
For quality control purposes; 5th and 6th
digits = week of production
For identification purposes; 7th to 16th
digits = product article number
For quality control purposes; 17th to 20th
digits = place of manufacture
... ecoTEC Plus ...
Product designation
2H / 2E / 3P / 2L...
Gas group and gas connection pressure
as set at the factory
II2H3P / I2E / I3P...
Approved gas category
Condensing techno-
logy
Efficiency class of the boiler in accord-
ance with EC Directive 92/42/EEC
Type: Xx3(x)
Permissible flue gas connections
PMS
Maximum water pressure in heating
mode
V
Hz
Electrical connection
–
Voltage
–
Fre-
quency
H
i
Lower gross calorific value
W
Max. electrical power consumption
IP
Protection class
Heating mode
Q
n
Nominal heating load range in heating
mode
P
n
Nominal heat output range in heating
mode
P
nc
Nominal heat output range in heating
mode (condensing technology)
Tmax
Maximum flow temperature
NOx
NOx class for the product
Code (DSN)
Specific product code
Read the instructions.
Note
Make absolutely sure that the product is compat-
ible with the gas group at the installation site.
3.3
Serial number
The serial number can be found on the identification plate.
3.4
CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.
4
Set-up
4.1
Unpacking the product
1.
Remove the product from its box.
2.
Remove the wedge and protective film from all of the
product's components.
4.2
Checking the scope of delivery
▶
Check that the scope of delivery is complete and intact.
Number
Designation
1
Heat generator
1
Bag of set-up parts with retainer for wall-mount-
ing and fastening accessories
1
Bag with condensate discharge hose
1
Cardboard box for the hydraulic connection with
expansion relief valve, drain cock, air separator
and seals
1
Enclosed documentation