24
Air/flue pipe installation manual 0020308120_02
Danger!
Risk of poisoning due to escaping flue
gas.
When disconnecting the pipes, flue gases
may escape.
▶
Ensure that the latching lug on the upper
side of the terminal securely snaps into
place in the flue pipe's recess.
▶
Ensure that the seal is positioned cor-
rectly.
2.
Install the deflector on the flue pipe.
3.
Slide the flue pipe, together with the deflector, back
into the air pipe so that both latching lugs snap into
place.
–
The air pipe's seam must lie at the top.
4.
Carefully slide the flue pipe back into the sleeve of the
pipe or elbow that are located behind it.
5.
Make sure that the two latching lugs snap into place.
6.
Install the wall seal on the deflector.
5.8.3.4 Adjusting the deflector
45°
45°
Danger!
Risk of poisoning due to escaping flue
gas.
The deflector may twist on its own if it is not
snapped into place. Flue gases may then
penetrate the building through windows and
ventilation openings.
▶
Turn the deflector to one of the three posi-
tions until you feel it snap into place.
1.
Set the terminal to the required position.
–
The flue gas stream is directed upwards at an
angle of approx. 45° when the deflector is set in the
centre position.
–
If necessary, the deflector terminal can be rotated
45° anti-clockwise or clockwise. This setting option
means that the flue system can be further optim-
ised.
1
2.
To remove the deflector from the air pipe, pull the
safety lug
(1)
downwards. This loosens both catches.
5.8.4
Black terminal set (article number 303934)
5.8.4.1 Scope of delivery
▶
Check the scope of delivery.
Summary of Contents for ecoTEC plus VU Series
Page 1: ...en Air flue pipe installation manual ecoTEC plus VU VUW VUI 0020308120_02 29 09 2022...
Page 57: ......