6
Operating instructions ecoTEC pro 0020129673_00
a
Safety
a
2
Caution!
>
Under no circumstances should you add frost protection
agents (or other additives, e.g. jointing compounds, cor-
rosion protection agents, etc.) to the heating water with-
out first consulting your qualified skilled tradesman. Oth-
erwise, this could result in damage to seals and dia-
phragms as well as noises during heating mode. Vaillant
assumes no liability for this or any consequential dam-
age.
Another way to protect the heating system and the boiler
from frost is to drain them. In doing so, you must ensure
that the heating system and boiler are completely drained.
>
Contact your approved heating specialist company for
advice on this.
Maintaining operation with an emergency power
generator in the event of a power cut
Your recognised heating specialist company connected your
boiler to the power mains during installation.
If the power supply is cut, it is possible that parts of the
heating installation may become damaged by frost.
If you want to maintain the operation of the boiler during a
power cut using an emergency power generator, take note
of the following:
>
Make sure that the technical values of this generator
(frequency, voltage, earthing) match those of the power
mains.
>
Contact your approved heating specialist company for
advice on this.
Changes to the surroundings of the boiler
You must not make any changes to the surroundings of the
boiler:
>
Never shut down the safety devices.
>
Do not tamper with any of the safety devices.
>
Do not make any changes:
– to the boiler
– to the gas, air, water and electricity supply lines,
– to the entire flue system,
– to the entire condensate drain system,
– to the expansion relief valve or the drain line and
– constructional conditions that could affect the opera-
tional reliability of the boiler
Cupboard Installation
>
If you require your boiler to be fitted into a kitchen type
cupboard then please consult your approved heating
specialist company. Under no circumstances must you
enclose your boiler yourself.
Enclosing the appliance in a cupboard requires compliance
with the special design instructions. This is to ensure all
necessary access is available for all necessary future
service requirements.
What to do if there are leaks in the hot water pipes
Take note of the following:
>
In the event of leaks, immediately close the cold water
stop valve in the domestic hot water pipework between
the boiler and the draw-off points.
>
Have the leak repaired by your approved heating special-
ist company.
With Vaillant ecoTEC pro boilers, the cold water stop valve
is not included in the scope of delivery of your boiler.
>
Ask your approved heating specialist company where
they fitted the cold water stop valve.
Preventing damage caused by low system pressure
in the heating installation
To prevent the heating installation being used when the
amount of water is too low and to therefore prevent any
subsequent damage that may be caused by this, note the
following:
>
Check the filling pressure of the heating installation at
regular intervals.
>
Always observe the information on filling pressure pro-
vided in
¬ Section 5.1.3
.
Requirements for the installation site
It is not necessary to keep a clearance between the boiler
and combustible materials or components since, at the
nominal heat output of your boiler, the temperature on the
surface of the casing is always lower than the maximum
permissible temperature of 85 °C.