flexoTHERM 230V

                               

Heat pump technical specification

  The flexoTHERM 230V heat pump is available in 5, 8 and 11kW models

  Connects to two different sources - ground or water

  One of the quietest heat pump ranges in the UK with Sound Safe System

  Green iQ for the highest energy efficiency

Summary of Contents for flexo THERM 230V

Page 1: ...ump technical specification The flexoTHERM 230V heat pump is available in 5 8 and 11kW models Connects to two different sources ground or water One of the quietest heat pump ranges in the UK with Sound Safe System Green iQ for the highest energy efficiency ...

Page 2: ...ging kg 161 176 188 Weight without packaging kg 151 166 178 Weight ready for operation kg 157 173 185 Connections 1 Recessed handles and cable duct 2 Heating flow 3 Heating return 4 Heating circuit diaphragm expansion tank connection 5 Hot water return 6 Connection From the heat source to the heat pump hot brine A 7 Connection From the heat pump to the heat source cold brine B 7 6 5 4 3 2 1 Dimens...

Page 3: ...flow return BSP male G 1 Heat source flow return BSP male G 1 Central heating water expansion vessel BSP male G Heating and brine right angle connections mm 35 Heat source circuit brine circuit Volume of the brine circuit in the heat pump l 2 5 3 1 3 6 Minimum pressure of brine fluid bar 0 7 Maximum pressure of brine fluid bar 3 0 Heating circuit building circuit Water volume of the heating circui...

Page 4: ...8 0 65 0 54 Minimum flow rate during continuous operation at the application limits l h 600 930 1290 Maximum flow rate during continuous operation at the application limits l h 930 1450 1930 Heating pump electrical power consumption for B0 W35 ΔT 3K with an external pressure loss of 250 mbar in the heating circuit W 24 37 49 Heating output B0 W35 ΔT 5K kW 5 30 8 90 11 20 Power consumption B0 W35 Δ...

Page 5: ...h 1025 1730 2270 Heating pump electrical power consumption for W10 W35 ΔT 5K with an external pressure loss of 250 mbar in the heating circuit W 24 37 49 Heating output W10 W35 ΔT 5K kW 6 40 10 00 12 90 Power consumption W10 W35 ΔT 5K kW 1 33 1 92 2 53 Output figure W10 W35 ΔT 5K coefficient of performance EN 14511 4 80 5 20 5 10 Heating output W10 W45 ΔT 5K kW 6 30 10 10 12 90 Power consumption W...

Page 6: ... 11kW 230V 4 97 4 48 3 99 3 89 3 79 flexoTHERM heat pumps Description Article number flexoTHERM 5kW 230V 0020257358 flexoTHERM 8kW 230V 0020257359 flexoTHERM 11kW 230V 0020257360 Accessories Description Article number fluoCOLLECT up to 11kW water source 0010016719 Passive cooling module up to 11kW 0010016721 flexoTHERM straight connection 0020212715 Brine filling station 0020106265 Glycol discharg...

Page 7: ...f control unit 0020259829 Wireless VRC 700f underfloor heating control pack 0020259830 Wireless VRC 700f two zone pack and DHW 0020259831 Wireless VRC 700f three zone pack and DHW 0020259832 Wireless VRC 700f one zone pack and solar DHW 0020259833 Wireless VRC 700f two zone pack and solar DHW 0020259835 VR 70 wiring centre 0020184844 VR 71 wiring centre 0020184847 Wired VR 91 programmable room the...

Page 8: ... find contact details for your nearest Vaillant sales representative Telephone 0345 602 0262 Technical Enquiries For technical assistance Telephone 0330 100 3540 Email aftersales vaillant co uk General Enquiries If you have a general enquiry our friendly reception staff will happily point you in the right direction Telephone 0345 602 2922 Training Enquiries Vaillant provide many different training...