Adapting the appliance to the heating system
86
Installation instructions geoTHERM 0020051574_04
9
9.7.3 Menu I: Display general information
Display shown
Description
Factory setting
Menu I: Displaying general information
In Menus I1 to I4 you can obtain information regarding
the settings for the heat pump.
Error History
I1
Fault number
>1
Fault code
96
10.03.10
07:18
Pressure sensor coolant error
Display of the error memory, showing the last 20
errors in the order they appeared.
The last fault to appear always has fault number 1.
The fault number is displayed with fault code, date/
time of occurrence and a brief fault description. The
error number shows the order in which the errors
occurred. The error code identifies the error. A list
can be found in
¬
Ch. 11
.
Turning the adjuster displays the next fault.
—
Statistics
I2
Compressor hours
7 hours
Compressor starts
33
Auxiliary heater operation
2 hours
Auxiliary heater starts
21
Compressor hours:
Compressor operating hours to
date.
Compressor starts:
Number of compressor starts to
date.
Auxiliary heater operation:
Auxiliary heater operat-
ing hours to date.
Auxiliary heater starts:
Number of auxiliary heating
starts to date.
—
Software versions
I3
I/O card
1
4.04
User Interface
1
3.04
VR 90
4
2.21
I/O card:
Software release I/O card (PCB in the heat
pump).
User interface:
User interface software version (dis-
play in the operating panel).
VR 90:
displays the software release when a VR 90 is
connected.
—
9.8