K
Lengths of the air/flue pipe
Length of the C13 type flue pipe
C13 type flue pipe
Dia. 60/100 (L)
Dia. 80/125 (L)
Length
of
the
air/flue
pipe
HOME COMBI 25 -A (H-GB)
≤
10 m
≤
25 m
HOME COMBI 30 -A (H-GB)
≤
10 m
≤
25 m
HOME COMBI 35 -A (H-GB)
≤
6 m
≤
19 m
Length of the C33 type flue pipe
C33 type flue pipe
Dia. 60/100 (L)
Dia. 80/125 (L)
Length
of
the
air/flue
pipe
HOME COMBI 25 -A (H-GB)
≤
10 m
≤
25 m
HOME COMBI 30 -A (H-GB)
≤
10 m
≤
25 m
HOME COMBI 35 -A (H-GB)
≤
10 m
≤
19 m
Length of the C43 type flue pipe
C43 type flue pipe
Dia. 60/100 (L)
Length
of
the
air/flue
pipe
HOME COMBI 25 -A (H-GB)
≤
10 m
HOME COMBI 30 -A (H-GB)
≤
10 m
HOME COMBI 35 -A (H-GB)
≤
10 m
L
Technical data
Technical data
–
Heating
HOME COMBI
25 -A (H-GB)
HOME COMBI
30 -A (H-GB)
HOME COMBI
35 -A (H-GB)
Maximum heating flow temperat-
ure (default setting)
75
℃
75
℃
75
℃
Max. range of the flow temperat-
ure regulation
10 … 80
℃
10 … 80
℃
10 … 80
℃
Maximum permissible pressure
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Nominal water flow (
Δ
T = 20 K)
655 l/h
655 l/h
655 l/h
Nominal water flow (
Δ
T = 30 K)
436 l/h
436 l/h
436 l/h
Approximate value for the
condensate volume (pH value
between 3.5 and 4.0) at 50/30 °C
1.53 l/h
1.53 l/h
1.53 l/h
Δ
P heating at nominal flow (
Δ
T =
20 K)
–
(bypass default setting)
0.025 MPa
(0.250 bar)
0.025 MPa
(0.250 bar)
0.025 MPa
(0.250 bar)
Δ
P heating at nominal flow (
Δ
T =
20 K)
–
(bypass closed)
0.041 MPa
(0.410 bar)
0.039 MPa
(0.390 bar)
0.042 MPa
(0.420 bar)
Technical data
–
G20 power/loading G20
HOME COMBI
25 -A (H-GB)
HOME COMBI
30 -A (H-GB)
HOME COMBI
35 -A (H-GB)
Maximum heat output (default set-
ting
–
d.00)
Automatic
Automatic
Automatic
Effective output range (P) at
50/30 °C
5.3 … 15.9 kW
6.3 … 15.9 kW
7.4 … 15.9 kW
Summary of Contents for home combi