Installation 4
0020224355_00 HOME Installation and maintenance instructions
9
4.4
Dimensions
A
C
B
D
Dimensions
A
B
C
D
740 mm
130 mm
300 mm
418 mm
4.5
Minimum clearances
A
A
D
B
C
Minimum clearances
A
B
C
D
D
≥
0 mm
≥
300 mm
≥
300 mm
≥
600 mm
≥
5 mm
Note
Cabinet-
type cas-
ing
4.6
Clearance from combustible components
It is not necessary to maintain a clearance between the
product and components made of combustible materials.
4.7
Using the installation template
▶
Use the installation template to ascertain the locations at
which you need to drill holes and make breakthroughs.
4.8
Wall-mounting the product
1.
Check whether the wall has sufficient load-bearing ca-
pacity to bear the operational weight of the product.
2.
Wall-mount the product as described using the adapted
fixing material provided on-site.
Conditions
: The load-bearing capacity of the wall is sufficient, The fixing
material may be used for the wall
A
B
▶
Wall-mount the product as described.
Conditions
: The load-bearing capacity of the wall is not sufficient
▶
Ensure that wall-mounting apparatus on-site has a suf-
ficient load-bearing capacity. Use individual stands or
primary walling, for example.
▶
Do not wall-mount the product if you cannot provide
wall-mounting apparatus with a sufficient load-bearing
capacity.
Summary of Contents for home combi