Operating and installation instructions 0020334316_02
Max. target flow temperature:°C
Enter the upper limit for the target flow temperature. The system
control compares the set value with the calculated target flow tem-
perature, and regulates to the smaller of these values.
Factory setting:
–
90 °C for a conventional heat generator
–
55 °C for a heat pump and/or mixed circuit
Set-back mode:
The behaviour can be adjusted separately for each heating circuit.
Factory setting:
Eco
Eco
The heating function is switched off and the frost protection func-
tion is activated.
At outdoor temperatures that are below 4 °C for longer than four
hours, the system control switches the heat generator on and reg-
ulates to the
Set-back temperature: °C
. At an outdoor temperat-
ure above 4 °C, the system control switches the heat generator off.
The monitoring of the outdoor temperature remains active.
Heating circuit behaviour outside of the time periods.
Prerequisite:
–
Time-contr.
is activated in the
MENU
|
CONTROL
|
Zone
|
Heating
|
Mode:
function.
–
Active
or
Inactive
is activated in the
Room temp. mod.:
func-
tion.
If
Expanded
is activated in the
Room temp. mod.:
, the system
control regulates to the target room temperature 5 °C independ-
ently of the outdoor temperature.
Normal
The heating function is switched on. The system control regulates
to the
Set-back temperature: °C
.
Prerequisite:
Time-contr.
is activated in the
MENU
|
CONTROL
|
Zone
|
Heating
|
Mode:
function.
Room temp. mod.:
The installed temperature sensor measures the current room tem-
perature. The system control calculates a new target room temper-
ature that is used to adjust the flow temperature.
–
Difference = Set target room temperature - current room tem-
perature
–
New target room temperature = Set target room tempe
difference
Prerequisite: In the
Zone assignment:
function, the system control
and/or the remote control is assigned to the zone in which the sys-
tem control or remote control is installed.
The
Room temp. mod.:
function is ineffective if
No assignmt
is
activated in the
Zone assignment:
function.
Factory setting:
Inactive
Inactive
Active
Adjusting the flow temperature based on the current room temper-
ature.
Expanded
Adjusting the flow temperature based on the current room temper-
ature. The system control also activates/deactivates the zone.
–
The zone is deactivated: Current room tempe 2/16 K >
set room temperature
–
Zone is activated: Current room temperature < set room tem-
perature - 3/16 K
Cooling possible:
Prerequisite: A heat pump is connected.
Factory setting;
No
Dew point monitoring:
The system control compares the set minimum cooling target flow
temperature with the current dew point + set dew point offset. The
system control selects the higher temperature for the target flow
temperature in order to prevent condensate.
Prerequisite: The
Cooling possible:
function has been activated.
Factory setting:
Yes
Min. cooling targ. flow temp.: °C
The system control regulates the heating circuit to the
Min. cool-
ing targ. flow temp.: °C
.
Prerequisite: The
Cooling possible:
function has been activated.
Factory setting: 20 °C
Summary of Contents for sensoCOMFORT VRC 720/3
Page 2: ...2 en Operating and installation instructions 3 en Country specifics 59...
Page 38: ...38 Operating and installation instructions 0020334316_02 4 9 2 3 Wiring diagram 0020184677...
Page 44: ...44 Operating and installation instructions 0020334316_02 4 9 4 5 Wiring diagram 0020177912...
Page 47: ...0020334316_02 Operating and installation instructions 47 4 9 5 5 Wiring diagram 0020280010...
Page 50: ...50 Operating and installation instructions 0020334316_02 4 9 6 5 Wiring diagram 0020260774...
Page 61: ......
Page 62: ......
Page 63: ......