4.3
System with FM5 and FM3 functional modules
VRC 720
eBUS
VR 92
FM5 (VR 71)
FM3 (VR 70)
Systems with more than two mixed heating circuits require the FM5 functional module.
The system may comprise the following:
–
Maximum 1 x FM5 functional module
–
Maximum 3 x FM3 functional modules, in addition to the FM5 functional module
–
Maximum 4 x
VR 92
remote controls, which can be installed in each heating circuit
–
Maximum 9 x heating circuits, which you achieve using 1 x FM5 functional module and 3 x FM3 functional modules
4.4
Potential application for the functional modules
4.4.1
FM5 functional module
Each configuration corresponds to a defined connection assignment of the FM5 (
Section 4.5) functional module.
Configura-
tion
System property
Mixed heat-
ing circuits
1
Solar heating and/or domestic hot water support with two solar cylinders
Max. 2
2
Solar heating and/or domestic hot water support with one solar cylinder
Max. 3
3
3 x mixed heating circuits
Max. 3
6
allSTOR
multi-functional buffer cylinder and domestic hot water station
Max. 3
4.4.2
FM3 functional module
If a FM3 functional module is installed, the system has one mixed and one non-mixed heating circuit.
The potential configuration (FM3) corresponds to a defined terminal assignment for the FM3 (
Section 4.6) functional
module.
Summary of Contents for sensoCOMFORT VRC 720/3
Page 2: ...2 en Operating and installation instructions 3 en Country specifics 59...
Page 38: ...38 Operating and installation instructions 0020334316_02 4 9 2 3 Wiring diagram 0020184677...
Page 44: ...44 Operating and installation instructions 0020334316_02 4 9 4 5 Wiring diagram 0020177912...
Page 47: ...0020334316_02 Operating and installation instructions 47 4 9 5 5 Wiring diagram 0020280010...
Page 50: ...50 Operating and installation instructions 0020334316_02 4 9 6 5 Wiring diagram 0020260774...
Page 61: ......
Page 62: ......
Page 63: ......