1. Introduction
Note: This boiler must be installed
and serviced by a competent person
in accordance with the Gas Safety
(Installation and Use) Regulations
1994. In the UK 'CORGI' Registered
Installers undertake the work to a
safe and satisfactory standard.
The TURBOmax is a fully
automatic, wall mounted, room sealed
combination boiler for central heating
and domestic hot water. Domestic hot
water is supplied directly from the
boiler, without requiring a copper
cylinder, cold water tank, feed and
expansion tank or associated
pipework. Domestic hot water has
priority over central heating.
The boiler has been designed for use
with a sealed central heating system,
and comes fully tested and assembled
with a built-in circulating pump,
bypass, expansion vessel and diverter
valve.
TURBOmax boilers carry 'CE' Mark.
This demonstrates that the boilers fulfill
the essential requirements of the Gas
Appliance Directive (90/396/EEC)
and the Gas Appliance (Safety)
Regulations 1992.
The 'CE' Mark also demonstrates that
the boilers comply with the
requirements of the Electromagnetic
Compatibility Directive (Directive
89/336/EEC), the Low Voltage
Directive (73/23/EEC), the Boiler
Efficiency Directive (92/42/EEC) and
the Boiler (Efficiency) Regulations
1993.
TURBOmax meets the requirements of
Statutory Instrument ‘The Boiler (Effi-
ciency) Regulations 1993 and
therefore is deemed to meet the
requirements of Directive 92/42/EEC
on the efficiency requirements for new
hot-water boilers fired with liquid or
gaseous fuels.
The TURBOmax range consists of
models with outputs for domestic hot
water of 24 and 28 kW. The boiler is
easily sited on any internal wall and
can be installed with either a horizontal
or vertical RSF (Room Sealed Fan
assisted) flue. Flue extensions and
additional bends and elbows are
available for increased siting flexibility.
(The boiler is not suitable for external
installation).
If desired an inhibitor may be used in
the system. Guidance on the use
of inhibitors is contained in these
instructions.
Natural Gas and LPG versions of the
boiler are available.
The boiler contains a domestic hot
water heat exchanger. The temperature
in the heat exchanger is limited by the
boiler control system and it is not
necessary to install a scale reducer on
the cold mains inlet to the boiler.
However, in exceptionally hard water
areas to prevent scale formation in the
property hot water system
pipework, a scale reducer may be
fitted.
The TURBOmax has built-in diagnostic
indicator lights which illuminate in
sequence giving information on the
boiler status when operating and per-
formance of key components to aid in
commissioning and fault finding.
The data badge is fitted on the bottom
of the combustion chamber.
See text of General Requirements for
Installation Requirements or notes.