Split Type Installation Manual
37
EN
PCB Explanation 9
The operation will be restarted up six minutes later, if T
is higher than TE7 for the second time within 10 minutes
after the start up, all of the output will be closed, and E8
will be displayed on the display panel.
• The louver opens to Standard Angle ANGLHEAT
when power is on for the first time
9.2
PCB Multi
9.2.1 Software Function · The definition of symbols
and wind speed
Ts
:
Setting Temperature
Tr
:
Room Temperature
Tp1
: Indoor Coil Temperature
The PG motor of the indoor fan is controlled by the
controllable silicon, the speed of which is divided into
three grades:
Heating mode
: High wind -> Mid wind -> Low wind ->
Slight breeze (The default value is 500rpm)
Cooling mode
: High wind -> Mid wind -> Low wind
Note!
The speed of high wind, mid wind and low wind in
cooling mode is in line with the corresponding
speed in heating mode, or the former is lower than
the latter
As for the slight breeze in heating mode with anti-
cool wind function: The indoor coil blows out the
slight breeze when the temperature is increased
from 25ºC to 30ºC
After powered on, the indoor fan will be started up
5 seconds later.
Model
Mode
High wind
Mid wind
Low wind
Slight breeze
Remark
Model 26
Heating
1100
1050
950
500
1.0
µ
F
Cooling
1100
950
800
Model 28
Heating
1300
1050
950
500
1.0
µ
F
Cooling
1300
1050
800
Model 32
Heating
1250
1050
950
500
1.0
µ
F
Cooling
1250
1050
800
Model 35
Heating
1300
1050
950
500
1.0
µ
F
Cooling
1300
1050
800
Summary of Contents for V 12-025 HWI
Page 30: ...Split Type Installation Manual 30 8 Photographs 8 5 Compresor 050 W 8 6 Compresor 065 W...
Page 31: ...Split Type Installation Manual 31 EN Photographs 8 8 7 PCB 025 035 MULTI...
Page 32: ...Split Type Installation Manual 32 8 Photographs 8 8 PCB 025 035W MONO...
Page 33: ...Split Type Installation Manual 33 EN Photographs 8 8 9 PCB 050 065W MONO...
Page 34: ...Split Type Installation Manual 34 8 Photographs 8 10 PCB OUTDOOR MULTI...