88
Installation Instructions VRC 630 0020095108_00
13 Technical data
13
Technical data
13.1
Technical data for the VRC 630
Parameter
Units
Control-
ler
Operating voltage
V AC/Hz
230 / 50
Power consumption of controller
VA
4
Contact load of the output relays (max.)
A
2
Maximum total current
A
6.3
Shortest switching interval
min
10
Power reserve
min
15
Maximum ambient temperature
°C
40
Sensor operating voltage
V
5
Minimum cross-section
- of the sensor lines
mm
2
0.75
- of the 230 V connection lines
mm
2
1.50
Dimensions of the wall box
Height
mm
292
Width
mm
272
Depth
mm
74
Level of protection
IP 20
Protection class of controller
I
Degree of ambient pollution
Normal
Table 13.1 Technical data for the VRC 630
13.2
Sensor characteristics
VR 10 sensor characteristics
(Flow, Return, Cylinder and Yield sensors)
Temperature in °C
R in kOhm
10
5.363
15
4.238
20
3.372
25
2.700
30
2.176
35
1.764
40
1.439
45
1.180
50
0.973
55
0.806
60
0.671
65
0.562
70
0.473
75
0.399
80
0.339
85
0.288
90
0.247
Table 13.2 VR 10 sensor characteristics
Characteristics of external sensor
Temperature in °C
R in kOhm
-25
2.167
-20
2.076
-15
1.976
-10
1.862
-5
1.745
0
1.619
5
1.494
10
1.387
15
1.246
20
1.128
25
1.02
30
0.92
35
0.831
40
0.74
Table 13.3 Characteristics of external sensor