3.10
Menus in different operating situations
In the Operator level
Wed 02.12.09
15:43
-3 °C
HK1
Auto
20 °C
HK2
Auto
20 °C
HK3
Auto
20 °C
HK4
Eco
22 °C
VRC 630
Example: Basic display
The basic display shows the current operating mode and the
required room temperature for each heating circuit and allows
the operating mode of each heating circuit to be changed quik-
kly. If more than two heating circuits are connected, these are
displayed in sequence when you turn the right hand
dial.
The basic data consisting of day of the week, date, time of day
and outside temperature are always shown in the upper area of
the display. If an error occurs, it is displayed in plain text in the
second line. Chapter 5.3 explains how to set the basic data.
Special operating modes and service functions can also be called
up in the basic display.
The arrow at the bottom right indicates that other modules
are connected to the controller.
When you want to check or set the operating mode or
temperature of these modules, simply turn the right hand dial to
access the next display lines.
Basic data
1
Date
02 . 12 . 09
Day
We
Time
14 : 08
Summer/Winter time
Off
>Set day
Example: Menu
1
You can make all the relevant settings for the heating installa-
tion on the Operator level in Menus (
1
to
7
).
The menu name and the menu number (in the example
1
) are
displayed in the upper area. The numbers make it easier to find
individual menus during programming.
Wed 02.12.09
15:37
- 15 °C
Energy saving enabled
to
18:30
VRC 630
Example: Special functions
Special functions temporarily change the operating mode of the
heating circuit and are ended automatically.
Special functions can only be called up from the
basic display
.
In the Installer level
HK1
C2
Parameters
Type of burner circuit
Night set back temp
15 °C
Heating curve
0.90
Max limit outside temp.
20°C
>Select target room temperature
Example: Menu C2
Menus
C1
to
C15
are where the system-specific parameters,
which only the heating engineer can set, are located.
These menus are identified by a 'C' and a number at the top right
of the display.
You can call up the menus in the Installer level and view the
parameters, but you cannot alter them.
Table 3.5 Menu types
The settable parameters are displayed on a grey back-
ground.
Description of the device 3
Operating manual VRC 630 0020095108_00
15
Summary of Contents for VRC 630
Page 1: ...GB VRC 630 3 ...
Page 2: ......
Page 54: ......
Page 55: ...For the heating engineer Installation Manual VRC 630 ...
Page 152: ...0020095108_00 GB 022010 Subject to alterations ...