Appendix
25
LegP: Legionella protection pump
Solar Yield: Solar yield
PWM: Start-up signal for the solar pump unit or the feedback signal
B.2
Configuring the inputs and outputs of the VR 70
Set
value
R1
R2
R3/R4
R5/R6
S1
S2
S3
S4
S5
S6
S7
1
HC1P
HC2P
MA
HC2op/
HC2cl
DHW1/
BufBt
DEM1
DEM2
SysFlow
FS2
3
MA
HC2P
LP/3WV
HC2op/
HC2cl
BufTop-
DHW
Buf
BtDHW
BufBtHC
SysFlow
BufTopHC FS2
5
HC1P
HC2P
HC1op/
HC1cl
HC2op/
HC2cl
SysFlow
DEM1
DEM2
FS1
FS2
6
COLP
LegP
MA
ZV1
DHW1
DHWBt
SysFlow
COL
Solar
Yield
PWM
12
COLP
HC1P
TDO/3WV HC2op/
HC2cl
Solar
Yield
DHWBt
TD1
TD2
COL
FS1
PWM
B.3
Configuring the outputs of the VR 71
Set
value
R1
R2
R3
R4
R6
R7/R8
R9/R10
R11/R12
3
HC2P
HC3P
HC4P
MA
LP/3WV
HC2op/
HC2cl
HC3op/
HC3cl
HC4op/
HC4cl
B.4
Configuring the inputs of the VR 71
Set
value
S1
S2
S3
S4
S5
S6
S7
S8
S9
3
SysFlow
FS2
FS3
FS4
BufBt
DEM2
DEM3
DEM4
DHW1
B.5
VR 70 sensor assignment
Set value
S1
S2
S3
S4
S5
S6
1
VR 10
VR 10
VR 10
3
VR 10
VR 10
VR 10
VR 10
VR 10
VR 10
5
VR 10
VR 10
6
VR 10
VR 10
VR 10
VR 11
VR 10
12
VR 10
VR 10
VR 10
VR 10
VR 11
VR 10
B.6
VR 71 sensor assignment
Set value
S1
S2
S3
S4
S5
S9
3
VR 10
VR 10
VR 10
VR 10
VR 10
VR 10
0020200781_01
VR
C
700/2
Installation instructions