Operating and display functions 8
0020131978_00 VRT 350f Installation instructions
23
8.2.2 Reading the water pressure of the heating
system
Menu
→
Installer level
→
System configuration
[
System
--
--]
→
Water pressure
–
This function allows you to read the water pressure of
the heating system.
8.2.3 Reading the hot water generation status
Menu
→
Installer level
→
System configuration
[
System
--
--]
→
Domestic hot water
–
You can use this function to read the hot water genera-
tion status (
Charged
,
Not charged
).
8.2.4 Reading the software version
Menu
→
Installer level
→
System configuration
[
System
--
--]
→
Control modules
–
You can use this function to read the software version
of the display, the heat generator and the radio receiver
unit.
8.2.5 Setting the control type
Menu
→
Installer level
→
System configuration
[
System
--
--]
→
Control type
–
Select this function to set the type of room temperature
control:
–
Two-point corresponds to an On/Off control system
–
Analogue corresponds to a modulating control system
8.2.6 Setting the distance adjustment
Menu
→
Installer level
→
System configuration
[
System
--
--]
→
Distance adjustment
–
This function allows you to optimally adjust the switching
behaviour of the controller to the room size or the radi-
ator layout:
–
Positive values: slower controller switching behaviour
–
Negative values: faster controller switching behaviour
The
Distance adjustment
function is only available if you
have set
Analogue
under the
Control strategy
function
8.3
System configuration: Heat generator
8.3.1
Reading the status of the heater
Menu
→
Installer level
→
System configuration
[
Heater 1
-
---]
→
Status
–
This function allows you to read the current status of the
heater (boiler).
Off
,
Heating
(heating mode),
hot water
generation
.