Address
RW
Type
Unit
Register
count
Description
0x0070
R
int16
ppb
1
Hydrogen sulfide (H
2
S) concentration in parts
per billion (ppb), without linear correction
• For a value with linear correction, use
register 0x0004
0x0071
R
int16
ppb
1
Trioxygen (ozone) (O
3
) concentration in parts
per billion (ppb), without linear correction
• For a value with linear correction, use
register 0x0005
0x0072
R
int16
ppb
1
Nitric oxide (NO) concentration in parts per
billion (ppb), without linear correction
• For a value with linear correction, use
register 0x0006
0x0073
R
int16
0.1 μg/m
3
1
Particulate matter PM
2.5
, without linear
correction
• For a value with linear correction, use
register 0x0008
0x0074
R
int16
0.1 μg/m
3
1
Particulate matter PM
10
, without linear
correction
• For a value with linear correction, use
register 0x0009
0x0075
R
int16
0.1 μg/m
3
1
Particulate matter PM
1
, without linear correction
• For a value without linear correction, use
register 0x0037
0x0076
R
int16
-
1
LPC data state
• 0 = LPC data not ready
• 1 = LPC data ready
0x007B
R
int16
-
1
LPC humidity invalidation flag
Combines all PM values from registers 0x007C -
0x007E
• 0 = LPC humidity ok
• 1 = LPC measurement may be invalid due to
high humidity
0x007C
R
int16
-
1
LPC humidity invalidation flag for PM
1
value
• 0 = LPC humidity is ok
• 1 = LPC PM
1
measurement may be invalid due
to high humidity
0x007D
R
int16
-
1
LPC humidity invalidation flag for PM
2.5
value
• 0 = LPC humidity is ok
• 1 = LPC PM
2.5
measurement may be invalid
due to high humidity
0x007E
R
int16
-
1
LPC humidity invalidation flag for PM
10
value
• 0 = LPC humidity is ok
• 1 = LPC PM
10
measurement may be invalid
due to high humidity
0x0086
RW
int16
-
1
CO linear correction gain value (1 ... 255,
corresponding gain values 0.01 ... 2.55)0
AQT530 Configuration Guide
M212572EN-C
50
Summary of Contents for AQT530