Example of Soil Temperature 2 Message
<SOH>TS2<STX> 12.9 E834<ETX><CR><LF><EOT>
4.11.13 Runway Temperature Message for AviMet
Runway Temperature Message Format
<SOH>TR1<STX> xxx.x <CRC16 %04d><ETX><CR><LF><EOT>
Name
Description
<SOH>TR1<STX>
Message header
xxx.x
Runway temperature (C), 1
‑
minute average
<CRC16 %04d>
Message checksum:
• Checksum span = Includes header, until checksum
<ETX><CR><LF><EOT>
Message trailer
Runway Temperature Message Characteristics
Property
Value
Default send interval
60 s
Polling command
TRREP
If there is no runway temperature data available, the message is substituted with the
following:
TR data missing<CR><LF>
Example of Runway Temperature Message
<SOH>TR1<STX> 25.8 26FB<ETX><CR><LF><EOT>
AWS310-SITE Configuration and Maintenance Manual
M211828EN-C
72
Summary of Contents for AWS310-SITE
Page 10: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 8 ...
Page 21: ...Chapter 2 Product Overview 19 ...
Page 22: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 20 ...
Page 62: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 60 ...
Page 86: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 84 ...
Page 140: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 138 ...
Page 148: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 146 ...
Page 150: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 148 ...
Page 152: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 150 ...
Page 166: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 164 ...
Page 172: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 170 ...
Page 174: ...AWS310 SITE Configuration and Maintenance Manual M211828EN C 172 ...
Page 175: ......
Page 176: ...www vaisala com ...