5.6.8 Replacing QSP431
If a QSP431 unit is faulty, replace it.
1. Remove the cable connectors.
1
1
2
1
Cable connectors
2
Clamp
2. Remove the unit. Press the top side of QSP431, grip the aluminum clamp on the
opposite side, and lift from the DIN rail.
3. Attach the new QSP431 unit and the cable connectors.
5.6.9 Replacing QML Data Logger
Only trained technicians are allowed to replace the QML data logger.
CAUTION!
Do not open the cover of the QML data logger in the field.
CAUTION!
AWS310-SITE Configuration and Maintenance Manual