3. Strip approximately 100 mm (4 in) of the cable, and cut the phase and neutral wires to the
length of approximately 50 mm (2 in). If you are using a stranded wire, add cable ferrules
to the ends.
Make sure that the grounding wire is longer than the phase
and neutral wires. Under mechanical stress, the grounding wire must be the
last to disconnect from the protective ground terminal.
CAUTION!
100 [3.94]
50 [1.97]
mm
[in]
1
2
3
Number
Wire
Wire color
(international)
Wire color
(North America)
Maximum wire cross-section
1
Phase L
Brown
Black
Solid wire: 4 mm
2
(12 AWG)
Stranded wire:
2.5 mm
2
(14 AWG)
2
Neutral N
Blue
White
Solid wire: 4 mm
2
(12 AWG)
Stranded wire:
2.5 mm
2
(14 AWG)
3
Grounding
PE/GND
Yellow/Green
Green
Solid wire: 4 mm
2
(12 AWG)
Stranded wire:
2.5 mm
2
(14 AWG)