# Turn logging on, choices are FILE or TERM or BOTH or NONE
LOG BOTH
• If you are starting the integrator from a terminal, set this to
BOTH
.
• If you are starting the integrator automatically, set this to
FILE
. The log file is stored
in
/usr/iris_data/log
.
•
IRIS_IN 30726
IRIS_IN_DIR /usr/iris_data/tdwr/
These entries configure the characteristics of the input from IRIS to the Integrator.
IRIS_IN
is the socket port that is used by IRIS to notify the Integrator when a new
product is sent. This must match the IRIS setup/output network device that has been
configured to send products from IRIS to the Integrator. The default port is 30726.
The
IRIS_IN_DIR
is the directory where IRIS sends products to the Integrator. This
must match the directory configured at the beginning of this section and the directory
configured in IRIS setup/output for the TDWR integrator. See
•
IRIS_OUT cyclone 30725
IRIS_OUT_DIR /usr/iris_data/product/
These entries configure the characteristics of the output from the Integrator to IRIS.
IRIS_OUT
is the nodename (cyclone) and socket port (30725) where IRIS will receive
the data. Usually this is the local workstation where the Integrator is running. The
socket port should match the
IRIS_NETRCV
environment variable for the network
receiver. This is set in the
/usr/sigmet/config/profile
.
The
IRIS_OUT_DIR
is the directory where TDWR products are sent. This must match
the directory configured for
IRIS_PRODUCTS
, typically
/usr/iris_data/
product
. This is set in the
/usr/sigmet/config/profile
.
•
IRIS_IN_TIME 120
This is the time in seconds, after which, an input is considered to be "stale". For
example, if the LLWAS stops sending data, the Integrator continues to use the old
LLWAS data for 120 seconds (in the example). After 120 seconds, the old LLWAS data is
not used to make new TDWR products.
IRIS Product and Display User Guide
M211319EN-H
358
RESTRICTED
Summary of Contents for IRIS
Page 1: ...M211319EN H RESTRICTED User Guide IRIS Radar IRIS Product and Display...
Page 12: ...IRIS Product and Display User Guide M211319EN H 10 RESTRICTED...
Page 71: ...Chapter 3 Configuring IRIS Products RESTRICTED 69...
Page 303: ...Figure 103 Typical Spectrum Plot Appendix A Basic Radar Meteorology RESTRICTED 301...
Page 386: ......
Page 392: ......
Page 393: ......
Page 394: ...www vaisala com...