12 Ethernet connection specification
207
Measurement results
The measurement result query gives the measured and calculated measurement val-
ues from the chosen sensor.
Request ID
0x00000004
Request data
0x00000000
: sensor A
Request data
0x00000001
: sensor B
Response keys
Status
: string, sensor status message
Slope
: float, image quality factor (QF)
PTraw
: integer, PT1000 value
LED
: float, sensor led value
RHsens
: float, sensor internal humidity
nD
: float, calculated n
D
value
CONC
: float, final concentration value
Tsens
: float, sensor internal temperature
T
: float, process temperature (with temperature bias)
Traw
: float, process temperature (without bias)
CCD
: float, image shadow edge
CALC
: float, calculated concentration value
DTR status
Request ID
0x00000006
Request data
(none)
Response key
*Volt1
: float, DTR internal voltage 1
*Volt2
: float, DTR internal voltage 2
*DTRtemp
: float, DTR internal temperature
Out1uA
: integer, mA output 1 in uA
Out2uA
: integer, mA output 2 in uA
Switches
: hex string (e.g. "0x00"), switch status as a bit field
12.5.3 Error message specification
If the server (DTR) does not recognize the request or cannot fulfill it, it responds with
an error message. The error message has the following keys:
*Error
: integer, error code
0x00000000
: Unknown request
*Error
: integer, error code
0x00000001
: Invalid request (request recognized,
invalid request data)
*Error
: integer, error code
0x00000002
: No sensor (sensor(s) not connected
to DTR)
ErrorMsg
: string, error details
There may also be error-dependent extra keys. Other error codes may be returned.
0x00000003
is to be handled as unknown request. Codes with higher numbers refer
to internal errors; contact Vaisala for more information on these.
Summary of Contents for K-PATENTS PR-23 AX Series
Page 1: ...IM EN PR23 v 2 00 Instruction Manual Vaisala K PATENTS Process Refractometer PR 23...
Page 2: ......
Page 4: ......
Page 17: ...2 Inline refractometer sensor 7 2 2 2 PR 23 mounting guide...
Page 26: ...16 PR 23 instruction manual...
Page 29: ...4 Prism wash systems 19 Figure 4 1 A prism wash system for steam non sanitary...
Page 30: ...20 PR 23 instruction manual Figure 4 2 A sanitary prism wash system for steam...
Page 32: ...22 PR 23 instruction manual Figure 4 5 Wiring for a prism wash system for steam...
Page 33: ...4 Prism wash systems 23 Figure 4 6 A prism wash system for high pressure water non sanitary...
Page 34: ...24 PR 23 instruction manual Figure 4 7 A sanitary prism wash system for high pressure water...
Page 35: ...4 Prism wash systems 25 Figure 4 8 Wiring for a prism wash system for high pressure water...
Page 40: ...30 PR 23 instruction manual...
Page 50: ...40 PR 23 instruction manual...
Page 72: ...62 PR 23 instruction manual...
Page 174: ...164 PR 23 instruction manual...
Page 179: ...11 Safe Drive 169 11 3 3 Safe Drive steam wash system parts...
Page 186: ...176 PR 23 instruction manual 11 4 2 Wiring Figure 11 9 PR 23 SD system wiring...
Page 204: ...194 PR 23 instruction manual Figure 11 19 Markings on the retractor handle...
Page 206: ...196 PR 23 instruction manual...
Page 218: ...208 PR 23 instruction manual...
Page 226: ...216 PR 23 instruction manual...
Page 230: ...220 PR 23 instruction manual...
Page 232: ...222...
Page 238: ...228...
Page 240: ...230...
Page 242: ...232...
Page 244: ...234...
Page 246: ...www vaisala com...