User's Guide _______________________________________________________________________
90 ___________________________________________________________________ M210243en-A
The mounting bracket (1 in Figure 87 below) is not included in the
sensor delivery. A rubber-lined ring clamp (3) and the screw (4) are
included with the sensor in the package. To install the sensor, follow
the procedure below:
1.
Slide the ring clamp (3) onto the sensor body (2) and connect
the cable to the sensor.
2.
Turn the sensor so that the two wire loops imbedded in the
wooden dowel will be horizontal. That is, the wires must be on
the sides of the sensor, not the top and bottom. Tighten the
clamp with the screw (4).
0201-041
Figure 87
Installing the Sensor with the Clamp
3.
Secure the slack in the cable to the tower leg or the sensor
bracket with a cable tie.
4.
Loosen and remove two hand screws beneath the tube. Slide the
tube down to expose the logger (see Figure 34 on page 53).
5.
Select one of the analog channels, CH1 ... CH3, and place the
connector to the selected input channel at the logger. The exact
channel depends on your configuration.
6.
Remove the connector from the selected temperature
measurement channel, that is, one of the channels CH4 ... CH7.
The removed cables and their connector are not needed. Insert
adapter QLA005 to the channel and place the connector on top
of it.