User's Guide _______________________________________________________________________
82____________________________________________________________________ M210543EN-B
The parameters of the
ACAL
command in the current range of
0 ... 20 mA are the following
DAC scale 21
DAC scale 20
Maintenance Commands
The maintenance commands are used in installation, maintenance, and
troubleshooting. They are as follows:
-
STA
, Displays status
-
CAL
Calibrator _frequency, Calibration
-
CLEAN
, Sets clean references
-
ZERO
, Displays zero and noise test status
-
CHEC
, Displays calibrator test signal
-
DRY ON
, Sets RAINCAP
®
dry offset
-
WET ON
, Sets RAINCAP
®
wet scale
-
TCAL
, Sets the TS temperature (ambient)
-
HEAT
, Pulls hood heater relays on
STA
The
STA
command (or
MES 3
command) displays the results from
the built-in test system as a status message.
The system output is the following:
PWD STATUS
VAISALA PWD22 V 1.00 2003-12-15 SN:Y46101
SIGNAL
3.43 OFFSET
146.11 DRIFT
0.00
REC. BACKSCATTER
2802
CHANGE
2
TR. BACKSCATTER
-2.3
CHANGE
0.0
LEDI
2.3
AMBL
-1.0
VBB
12.6
P12
11.4
M12
-11.3
TS
24.6
TB
29
TDRD
24
25
DRD
858
854
DRY
857.5
BL
26
RELAYS
OFF OFF OFF
HOOD HEATERS OFF
HARDWARE :
OK