2. Installing device

2.1 

Select the installation 

height. 

The recommended 

installation height is 

2 ... 5 meters (6 ... 16 ft).

Low installation height 

is more representative 

of the temperature and 

relative humidity near 

the road surface.

For the surface temperature measurement, select the 

installation height so that you can aim the sensor at 

the desired measurement point (max. tilt angle 60°).

Note!

 

A large tilt angle may extend the surface 

temperature measurement area outside the desired 

measurement point.

2.2 

Fasten the mounting 

bracket. Cut off excess 

steel band or place it 

neatly into the bracket.

2.3 

Use the locking key 

to lift and secure the 

device to the bracket. 

Remove the locking key.

SNAP!

Tilt angle

60° 

Tilt angle

10° 

2 ... 5 m

(6 ... 16 ft)

Desired

measurement

point

Summary of Contents for TempCast FMP102

Page 1: ...M212844EN A Setup Guide VaisalaTempCast FMP102 FMP103...

Page 2: ......

Page 3: ...that the installation location is within the NB IoT network coverage area of the network operator Mount the device on a pole mast with diameter 60 425 mm 2 36 16 73 in FMP103 1 Temperature and relativ...

Page 4: ...Vaisala Cast Connect mobile application 7 mm socket wrench or flat head screwdriver Tin snips for cutting steel band Aerial work platform Protective clothing PPE Road safety equipment To set up the de...

Page 5: ...the Measurements tab to view the device measurements 1 5 Select Start activation Follow the onscreen instructions 1 4 Check the signal strength from the Connection tab and wait until the cloud connect...

Page 6: ...installation height so that you can aim the sensor at the desired measurement point max tilt angle 60 Note A large tilt angle may extend the surface temperature measurement area outside the desired me...

Page 7: ...ent tool on the sensor The tool can be positioned on either side of the device 3 3 Look through the alignment tool to aim the sensor at the measurement point Tighten the finger screws and remove the t...

Page 8: ...oid phone with NFC reader and Bluetooth Vaisala Cast Connect mobile application Protective clothing Road safety equipment 3 mm Allen key At the end of its 3 year lifetime the device needs to be replac...

Page 9: ...to activate the device The new device is sending measurements to the cloud 1 6 Lift the new device to the bracket FMP103 only 1 3 Copy the surface temperature sensor angles to the new device 1 2 Turn...

Page 10: ...e battery in an environment surrounded by extremely high temperatures Extremely high temperature can result in an explosion or the leakage of flammable liquid or gas WARNING Make sure that the battery...

Page 11: ...increasing reuse and recycling and reducing the amount of WEEE going to landfill This symbol indicates that the product should be collected separately from other waste streams and treated appropriatel...

Page 12: ...ulations on occupational safety WARNING The sensor contains batteries which poses a fire explosion and severe burn hazard Do not crush disassemble heat above 100 C 212 F or incinerate WARNING The batt...

Reviews: