background image

 

2

ITEM DESCRIPTION MATERIAL 

1 Body 

 

HDPE 

Rubber Membrane 

High Grade Neoprene

3 Damper 

Seal 

 

PETG 

Body Bolt 

 

T316 Stainless Steel 

WARNING:  If the FrostSafe™ is installed 

downstream of an air valve, the 
air valve’s isolation valve must be 
closed prior to performing 
inspection or maintenance of the 
FrostSafe

.  Failure to close the 

isolation valve could lead to 
bodily injury if the air valve 
discharges air during inspection.

 

 

        
  Figure 2. Typical Installation 

 
 

FROSTSAFE™ CONSTRUCTION

 

The standard FrostSafe™ is constructed of quality 
corrosion resistant materials including high density 
polyethylene (HDPE) and Stainless steel type 316 
bolts.  The general details of construction are 
illustrated in Figure 3 and identified in Table 2. 
 
 

 

Figure 3: FrostSafe

 Cross Section of 

Components 

 
 

Table 2: FrostSafe

 Parts List 

 

 

 

MAINTENANCE

 

The FrostSafe™ requires no scheduled lubrication 
or maintenance. 
 

INSPECTION:  The FrostSafe

 may be checked for 

debris by following the disassembly and reassembly 
instructions.  The body may be checked for cracks 
and gouges and the damper seal for tears.  The 
rubber membranes may be inspected for aging, 
tears or deep scratches. 

 
TROUBLESHOOTING

 

Troubleshooting is presented below to assist you 
with the FrostSafe™ in an efficient manner. 
 

• 

FrostSafe

 Stuck Open:  Clean and inspect the 

damper seal and rubber membranes for debris. 

 
 

 

DISASSEMBLY

 

 
1. Loosen the pipe flange bolts, separate the flanges 

and remove the FrostSafe

 
2. Use an Allen wrench to remove the button head 

cap screws (4). 

 
3. Pull the body halves apart to inspect the damper 

seal (3) and the rubber membranes (2). 

 

REASSEMBLY

 

All parts must be clean.  Worn or damaged parts 
should be replaced during reassembly. 
 
1. Insert screws into counterbores of one of the 

damper bodies (1). 

 
2. Place one of the rubber membranes (2) into the 

register making sure to put the screw through one 
of the bolt holes cut into the membrane. 

 
3. Lay the plastic damper seal (3) on top of the 

rubber membrane (2) making sure to align the cut 
patterns for proper mating. 

 
4. Place the other rubber membrane (2) on top of 

the damper seal completing the three-layer 
structure.  Again, make sure to align the cut 
patterns for proper mating. 

Summary of Contents for FrostSafe Two-Way Damper

Page 1: ...al INTRODUCTION 1 RECEIVING AND STORAGE 1 DESCRIPTION OF OPERATION 1 INSTALLATION 1 CONSTRUCTION 2 MAINTENANCE 2 TROUBLESHOOTING 2 DISASSEMBLY 2 REASSEMBLY 2 PARTS AND SERVICE 3 WARRANTY 3 VAL MATIC VALVE AND MANUFACTURING CORP 905 RIVERSIDE DR ELMHURST IL 60126 TEL 630 941 7600 FAX 630 941 8042 ...

Page 2: ... extended period DESCRIPTION OF OPERATION The FrostSafe is a wafer style hingeless 2 way damper that prevents cold air from entering the vault reservoir or air valve while still allowing the vent to perform its function of admitting and expelling air under normal operating conditions INSTALLATION The installation of the FrostSafe is important for its proper operation The FrostSafe can be installed...

Page 3: ... instructions The body may be checked for cracks and gouges and the damper seal for tears The rubber membranes may be inspected for aging tears or deep scratches TROUBLESHOOTING Troubleshooting is presented below to assist you with the FrostSafe in an efficient manner FrostSafe Stuck Open Clean and inspect the damper seal and rubber membranes for debris DISASSEMBLY 1 Loosen the pipe flange bolts s...

Page 4: ...he foregoing NO OTHER WARRANTIES WRITTEN OR ORAL EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE MADE OR AUTHORIZED NO AFFIRMATION OF FACT PROMISE DESCRIPTION OF PRODUCT OF USE OR SAMPLE OR MODEL SHALL CREATE ANY WARRANTY FROM MANUFACTURER UNLESS SIGNED BY THE PRESIDENT OF THE MANUFACTURER These products are not manufactured sold or intended ...

Reviews:

Related manuals for FrostSafe Two-Way Damper